TY - JOUR
T1 - 3-D finite element simulation of the cylinder temperature distribution in boil-off gas (BOG) compressors
AU - Shen, Yuhong
AU - Zhang, Bo
AU - Xin, Dianbo
AU - Yang, Donghui
AU - Peng, Xueyuan
PY - 2012/11
Y1 - 2012/11
N2 - The boil-off gas (BOG) compressor is one of the most critical pieces of equipment in the handling of boiloff gas from liquefied natural gas (LNG). It ensures the safety of the transportation and receiving systems of LNG. This study used a three-dimensional finite element model to investigate the heat transfer process in the cylinder of a BOG compressor. The results showed that when the BOG compressor was running steadily, the average temperatures of the suction chamber and the discharge chamber were ~-109 °C and ~-60 °C, respectively. The temperature of the compression chamber was between these two values. Simulations of the temperature of the inner surface of the cylinder showed that more than 60% of the total temperature drop occurred within the first ten minutes of the compressor's operation, and that the largest temperature difference between various parts of the cylinder also occurred during this period. Thereafter, the temperature gradually decreased until it reached a dynamically stable state. Finally, it was proven that temperature fluctuation only existed on the inner surface of the cylinder and that its amplitude was lower than 0.003 °C. Accordingly, the global temperature can be regarded as invariable.
AB - The boil-off gas (BOG) compressor is one of the most critical pieces of equipment in the handling of boiloff gas from liquefied natural gas (LNG). It ensures the safety of the transportation and receiving systems of LNG. This study used a three-dimensional finite element model to investigate the heat transfer process in the cylinder of a BOG compressor. The results showed that when the BOG compressor was running steadily, the average temperatures of the suction chamber and the discharge chamber were ~-109 °C and ~-60 °C, respectively. The temperature of the compression chamber was between these two values. Simulations of the temperature of the inner surface of the cylinder showed that more than 60% of the total temperature drop occurred within the first ten minutes of the compressor's operation, and that the largest temperature difference between various parts of the cylinder also occurred during this period. Thereafter, the temperature gradually decreased until it reached a dynamically stable state. Finally, it was proven that temperature fluctuation only existed on the inner surface of the cylinder and that its amplitude was lower than 0.003 °C. Accordingly, the global temperature can be regarded as invariable.
KW - Boil-off gas compressor
KW - Finite element method
KW - Heat transfer
KW - Temperature distribution
UR - https://www.scopus.com/pages/publications/84865798232
U2 - 10.1016/j.ijheatmasstransfer.2012.07.057
DO - 10.1016/j.ijheatmasstransfer.2012.07.057
M3 - 文章
AN - SCOPUS:84865798232
SN - 0017-9310
VL - 55
SP - 7278
EP - 7286
JO - International Journal of Heat and Mass Transfer
JF - International Journal of Heat and Mass Transfer
IS - 23-24
ER -