摘要
To ensure the safety and efficient operation of power batteries, a three-dimensional numerical model of a stagger-arranged battery pack was established to explore the effects of air supply velocity, number of fins, and thermal conductivities of fins and fixed parts on the thermal characteristics and pressure drop inside the battery pack. Numerical results show that the fixed parts made of traditional epoxy (λ=0.2 W·m-1·K-1) between batteries more significantly increase the maximum temperature inside the battery pack compared with the case without fixed parts, and the temperature difference between these two cases is about 12 K. Moreover, the difference of pressure drop between these two cases gradually increases with Reynolds number. It is demonstrated that the numerical model of the stagger-arranged battery pack without fixed parts distinctly underestimates the maximum temperature and pressure drop. As air coolant is of laminar flow inside the stagger-arranged battery pack, the optimal thermal conductivity of fixed parts is 2 W·m-1·K-1. The temperature distribution inside the battery pack can be improved effectively by the fins associated with an increment of pressure drop less than 10%.
| 投稿的翻译标题 | Numerical Investigation for Hotspots of Stagger-Arranged Lithium-Ion Battery Stack with Air Cooling Strategy |
|---|---|
| 源语言 | 繁体中文 |
| 页(从-至) | 25-31 and 138 |
| 期刊 | Hsi-An Chiao Tung Ta Hsueh/Journal of Xi'an Jiaotong University |
| 卷 | 52 |
| 期 | 7 |
| DOI | |
| 出版状态 | 已出版 - 10 7月 2018 |
关键词
- Air cooling
- Hotspot
- Lithium-ion battery
- Pressure drop
- Thermal resistance
学术指纹
探究 '锂电池组高温节点空气冷却方案的数值模拟' 的科研主题。它们共同构成独一无二的学术指纹。引用此
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver