跳到主要导航 跳到搜索 跳到主要内容

相变套管式储热系统放冷性能实验研究

  • University of Shanghai for Science and Technology

科研成果: 期刊稿件文章同行评审

5 引用 (Scopus)

摘要

In this paper, a casing type phase change heat storage experiment system is set up, which is filled with composite phase change materials made of expanded graphite and n-pentadecane with different mass fractions, and the system is charged and discharged repeatedly. The heat transfer enhancement of the sleeve tube thermal storage system was characterized by effective heat storage ratio Est and energy storage efficiency ε. The results show that the discharging process was completed by 1770 s (Condition A, kp =0.14 W•m-1•K-1). The completed time for Condition B (kp =7.10 W•m-1•K-1) and Condition C (kp =11.60 W•m-1•K-1) were shortened by 77.3% and 78.9% under the same Reynolds number. Est and ε of the system increase significantly with the increasing thermal conductivity. As the thermal conductivity increases from 0.14 W•m-1•K-1 to 11.60 W•m-1•K-1, Est increased by 33.3%, 350.0% and 129.6% in the laminar region, transition region and turbulent region, and ε increased by 26.8%, 52.9% and 14.6% respectively. However, Est and ε decrease as Re increases in Condition B and Condition C. Est in Condition C shows a peak of 1.62 at Re = 4298.

投稿的翻译标题Experimental study of phase change sleeve tube thermal storage system performance during charging
源语言繁体中文
页(从-至)1580-1587
页数8
期刊Huagong Xuebao/Journal of Chemical Industry and Engineering (China)
71
4
DOI
出版状态已出版 - 1 4月 2020

关键词

  • Composites
  • Effective heat storage ratio
  • Heat Conduction
  • Phase change
  • Phase change sleeve tube thermal storage system

学术指纹

探究 '相变套管式储热系统放冷性能实验研究' 的科研主题。它们共同构成独一无二的指纹。