摘要
The main feedwater pump frequency-doubled vibration occurred in Tianwan NPP units 3 and 4 in the process of commissioning. The frequency-doubled is approximately equal to the three times frequency of the pump structure according to the result of modal test. The three times frequency of the pump structure is increased by reinforcing the pedestal of the main feedwater pump. According to the test result, the vibration of the bearing pedestal is reduced obviously. The reinforcement results in good effect.
| 投稿的翻译标题 | Causal Analysis and Resolution of Main Feedwater Pump Frequency-Doubled Vibration of Tianwan NPP Units 3 and 4 |
|---|---|
| 源语言 | 繁体中文 |
| 页(从-至) | 79-80 |
| 页数 | 2 |
| 期刊 | Hedongli Gongcheng/Nuclear Power Engineering |
| 卷 | 39 |
| 期 | 6 |
| DOI | |
| 出版状态 | 已出版 - 15 12月 2018 |
关键词
- Frequency adjustment
- Main feedwater pump
- Vibration
学术指纹
探究 '田湾核电站3、4号机组主给水泵2倍频振动原因分析与处理' 的科研主题。它们共同构成独一无二的学术指纹。引用此