跳到主要导航 跳到搜索 跳到主要内容

田湾核电站3、4号机组主给水泵2倍频振动原因分析与处理

  • Di Zhao
  • , Xiaomeng Chen
  • , Xiufeng Wang
  • , Zhongzhi Sun
  • , Zhengping Zhou
  • , Zhijun Zhou
  • , Guanghui Hu
  • CNNP Jiangsu Nuclear Power Co. Ltd.

科研成果: 期刊稿件 › 文章 › 同行评审

2 引用 (Scopus)

摘要

The main feedwater pump frequency-doubled vibration occurred in Tianwan NPP units 3 and 4 in the process of commissioning. The frequency-doubled is approximately equal to the three times frequency of the pump structure according to the result of modal test. The three times frequency of the pump structure is increased by reinforcing the pedestal of the main feedwater pump. According to the test result, the vibration of the bearing pedestal is reduced obviously. The reinforcement results in good effect.

投稿的翻译标题Causal Analysis and Resolution of Main Feedwater Pump Frequency-Doubled Vibration of Tianwan NPP Units 3 and 4
源语言繁体中文
页(从-至)79-80
页数2
期刊Hedongli Gongcheng/Nuclear Power Engineering
卷39
期6
DOI
出版状态已出版 - 15 12月 2018

关键词

  • Frequency adjustment
  • Main feedwater pump
  • Vibration