跳到主要导航 跳到搜索 跳到主要内容

基于降阶模型的反应堆压力容器保温结构传热性能逆优化设计

  • Jie Zhao
  • , Yanjun Dai
  • , Yungang Wang
  • , Zhenyuan Guo
  • , Fan Bai
  • School of Energy and Power Engineering

科研成果: 期刊稿件 › 文章 › 同行评审

摘要

[Background] Thermal leakage in reactor pressure vessel (RPV) insulation structure poses safety risks, and traditional trial-and-error parameter optimization methods are inefficient for handling complex variables. [Purpose] This study aims to develop a proper orthogonal decomposition (POD)-based inverse design methodology to enhance the thermal performance of RPV insulation structure. [Methods] Firstly, three design variables (air supply temperature, RPV outer wall temperature, and installation gap) and their corresponding level numbers were systematically determined, and three optimization objectives were defined as average heat flux (qave), average temperature (Tave) on the RPV insulation's outer wall, and maximum local temperature (Tmax) of the concrete. Then, a comprehensive dataset comprising 24 computational fluid dynamics (CFD) simulations was generated through full factorial design method, with these computational results employed as POD snapshots. Finally, the validated POD method was employed to reconstruct 275 working condition cases, and a dimensionless comprehensive score (FPOD) on a percentage scale was established to evaluate the overall heat transfer performance based on the three optimization objectives. [Results] Calculation results show the POD reconstruction achieved high fidelity is achieved by the POD reconstruction, with an average determination coefficient (R2) exceeding 0.95 and mean relative deviation (MRD) below 2.87%, while reducing CPU time is reduced by 99% compared to CFD. The optimal variable combination (2 mm-16 ℃-309.5 ℃) yieldeds a comprehensive score (FPOD) of 97.4, improving overall heat transfer performance by 59.2% over the original design. [Conclusions] Results of this study demonstrate that the POD-based inverse design methodology provides an efficient and accurate approach for RPV insulation structure optimization. The optimal parameter combination achieves significant improvements in thermal performance, with qave reduced to 84.89 W·m−2, Tave to 35.21 ℃, and Tmaxto 72.86 ℃, which significantly enhances the safety and operational efficiency of RPV insulation structure.

投稿的翻译标题Inverse optimization design of heat transfer performance for the reactor pressure vessel insulation structure based on reduced-order model
源语言繁体中文
期刊论文编号010608
期刊He Jishu/Nuclear Techniques
卷49
期1
DOI
出版状态已出版 - 1月 2026
已对外发布是

关键词

  • Inverse design
  • Numerical simulation
  • Proper orthogonal decomposition (POD)
  • Reduced-order model
  • RPV insulation structure

学术指纹

探究 '基于降阶模型的反应堆压力容器保温结构传热性能逆优化设计' 的科研主题。它们共同构成独一无二的学术指纹。

引用此