摘要
For finned-tube heat exchangers, owing to the extremely different refrigerant pressure drop characteristics between evaporation and condensation modes, the optimum refrigerant channel number of the evaporation mode is larger than that of the condensation mode. However, the conventional heat exchanger cannot achieve better matching characteristics between the refrigerant circuit and variations in operating conditions. To solve this problem, a vapor-bypassed evaporation technique is applied in a residential air conditioner, and experimental studies have been conducted to investigate the corresponding system performance under various operating conditions. Experimental results show the following: under heating mode, as the heating capacity ranges 2~ 5 kW, the vapor-bypassed evaporation system yields 2.5%~7.2% higher COP over baseline; under cooling mode, when the cooling capacity increases from 1.5 kW to 4.5 kW, the COP of vapor-bypassed evaporation system is improved by 8. 6%~3. 5% in comparison with the baseline; finally, according to the GB 21455-2019 Standard[1], the APF (annual performance factor) of vapor-bypassed evaporation system is improved by 6.4%.
| 投稿的翻译标题 | Improving the APF Index of Inverter Air Conditioner Using Vapor-bypassed Evaporation Technique |
|---|---|
| 源语言 | 繁体中文 |
| 页(从-至) | 28-34 |
| 页数 | 7 |
| 期刊 | Journal of Refrigeration |
| 卷 | 42 |
| 期 | 4 |
| DOI | |
| 出版状态 | 已出版 - 8月 2021 |
关键词
- APF index
- fined-tube heat exchanger
- residential air conditioner
- vapor-bypassed evaporation technique