Skip to main navigation Skip to search Skip to main content

Water hammer characteristics of integral pressurized water reactor primary loop

  • Xi'an Jiaotong University
  • Nuclear Power Institute of China

Research output: Contribution to journalArticlepeer-review

21 Scopus citations

Abstract

The present work discussed the single-phase water hammer phenomenon, which was caused by the four-pump-alternate startup in an integral pressurized water reactor (IPWR). A new code named water hammer program (WAHAP) was developed independently based on the method of characteristic to simulate hydraulic transients in the primary system of IPWR and its components such as reactor core, once-through steam generators (OTSG), the main coolant pumps and so on. Experimental validation for the correctness of the equations and models in WAHAP was carried out and the models fit the experimental data well. Some important variables were monitored including transient volume flow rates, opening angle of valve disc and pressure drop in valves. The water hammer commercial software Flowmaster V7 was also employed to compare with WAHAP and the good agreement can validate the equations in WAHAP. The transient results indicated that the primary loop of IPWR suffers from slight water hammer impact under pump switching conditions.

Original languageEnglish
Pages (from-to)165-173
Number of pages9
JournalNuclear Engineering and Design
Volume261
DOIs
StatePublished - 2013

Keywords

  • Water hammer Integral pressurized water reactor Method of characteristic Experimental verification Flowmaster

Fingerprint

Dive into the research topics of 'Water hammer characteristics of integral pressurized water reactor primary loop'. Together they form a unique fingerprint.

Cite this