Skip to main navigation Skip to search Skip to main content

Ultrasound Transcranial Imaging Based on Fast Coherent-Time-Delay and Correlative Pixel-Based Beamforming

  • Chen Bai
  • , Xinyu Zhang
  • , Xiaoyang Qiao
  • , Yuchao Sang
  • , Hui Zhong
  • , Mingxi Wan
  • Xi'an Jiaotong University
  • CAS - Xi'an Institute of Optics and Precision Mechanics

Research output: Chapter in Book/Report/Conference proceedingConference contributionpeer-review

4 Scopus citations

Abstract

Adaptive beamforming, such as the fast minimum variance (FMV)algorithm, has been developed to improve the contrast-to-noise ratio (CNR)in plane wave imaging with extremely reduced computation. However, in ultrasound trans cranial imaging, FMV will be confronted with challenges raised by echoes with low intensities, especially when calculating the beamformer contributions at points which are in a distance from the beam center line. In order to improve the CNR and resolution in low echo beamforming during trans cranial imaging, this paper proposed an adaptive beamforming which combined with fast minimum variance (FMV)algorithm and unified pixel-based beamforming, i.e. fast coherent-time-delay and correlative pixel-based (FCCP)beamforming. By considering the influence of neighboring pixels during the beamforming, this method can remove undesirable information instead of increasing diagnostic information in trans cranial imaging. The influence of neighboring pixels was reflected by coherent-time-delay and coherent coefficients of each covariance matrix. After the simulation and phantom study, the results prove that CNR and the resolution are indeed ameliorated be FCCP, compared with delay-and-sum (DAS)and conventional minimum variance (MV)algorithm. In simulation, the CNR was augmented by 6 dB as well as the lateral resolution was improved by from 0.1536 mm from 0.1740 mm. FCCP is the combination of compound coherent-time-delay and correlative pixel-based, which could improves the resolution and contrast if image, and FMV. FMV is involved for the high complexity caused by matrix inversion, the computation was simplified by principal component analysis (PCA)when calculate the covariance matrix.

Original languageEnglish
Title of host publication2018 IEEE International Ultrasonics Symposium, IUS 2018
PublisherIEEE Computer Society
ISBN (Electronic)9781538634257
DOIs
StatePublished - 17 Dec 2018
Event2018 IEEE International Ultrasonics Symposium, IUS 2018 - Kobe, Japan
Duration: 22 Oct 201825 Oct 2018

Publication series

NameIEEE International Ultrasonics Symposium, IUS
Volume2018-October
ISSN (Print)1948-5719
ISSN (Electronic)1948-5727

Conference

Conference2018 IEEE International Ultrasonics Symposium, IUS 2018
Country/TerritoryJapan
CityKobe
Period22/10/1825/10/18

Keywords

  • coherent coefficient
  • coherent delay
  • correlative points
  • plane wave imaging
  • transcranial imaging

Fingerprint

Dive into the research topics of 'Ultrasound Transcranial Imaging Based on Fast Coherent-Time-Delay and Correlative Pixel-Based Beamforming'. Together they form a unique fingerprint.

Cite this