Skip to main navigation Skip to search Skip to main content

Transient operating characteristics and performance comparison of R290 and R134a in an electric vehicle scroll compressor

  • Zhiming Xu
  • , Junling Shen
  • , Haoyu Hu
  • , Wenyi Wang
  • , Xu Yang
  • , Feng Cao
  • School of Energy and Power Engineering
  • Ltd.

Research output: Contribution to journal › Article › peer-review

Abstract

R290 has a low global warming potential (GWP) and favorable thermophysical properties, making it a candidate refrigerant for electric vehicle thermal management systems (EVTMSs) to replace R134a. However, the effects of its distinct thermophysical properties on the transient internal flow and thermodynamic processes within the working chambers of scroll compressors remain insufficiently understood. In this research, an experimentally validated three-dimensional transient computational fluid dynamics (CFD) model is employed to investigate the operating characteristics of R290 and R134a using the same scroll compressor geometry. Both radial and unilateral axial gaps are considered in this model. Particular attention is given to the evolution of transient chamber pressure, temperature, leakage, and gas forces, while the volumetric efficiency, isentropic efficiency, compressor power, and cooling capacity are also compared between the two refrigerants. Results show that R290 exhibits more intense leakage flow through both gaps than R134a. At the 0° reference angle, the maximum difference in leakage velocity reaches 59.9 m·s−1, accompanied by more pronounced pressure and temperature asymmetries within the R290 working chambers. The average tangential and axial gas forces for R290 increase respectively by 27.6% and 51.6%. At 2000 rev·min−1, the greater leakage losses associated with R290 result in a lower cooling capacity than that obtained with R134a. As the rotary speed increases, the relative influence of leakage losses diminishes, and the cooling capacity with R290 is approximately 1.2 times that with R134a at 5000 rev·min−1. These findings demonstrate that mitigating gap leakage, particularly through improved axial sealing, is an important consideration in the optimization of an R290-specific scroll compressor.

Original languageEnglish
Article number107192
JournalInternational Journal of Refrigeration
Volume193
DOIs
StatePublished - Jan 2027
Externally publishedYes

Keywords

  • Leakage
  • R290
  • Scroll compressor
  • Transient analysis

Fingerprint

Dive into the research topics of 'Transient operating characteristics and performance comparison of R290 and R134a in an electric vehicle scroll compressor'. Together they form a unique fingerprint.