Abstract
On the basis of the classification and definitions of two regions of pressure drop oscillation in our previous work, the transient and time-averaged heat transfer characteristics of steam-water two-phase flow during the second regional pressure drop oscillation were experimentally studied in a closed circulation system with a helical coiled tube boiling channel. New non-dimensional parameters and criterion for characterizing the effects of second regional pressure drop oscillation on transient and time-averaged heat transfer coefficient were proposed.
| Original language | English |
|---|---|
| Pages (from-to) | 353-357 |
| Number of pages | 5 |
| Journal | Huagong Xuebao/Journal of Chemical Industry and Engineering (China) |
| Volume | 51 |
| Issue number | 3 |
| State | Published - Jun 2000 |
Fingerprint
Dive into the research topics of 'Transient and time-averaged oscillatory heat transfer of two-phase flow during second regional pressure-drop oscillation in helical coiled tube'. Together they form a unique fingerprint.Cite this