Abstract
An experimental research was carried out in a helical coiled tube of a closed-circulation loop under medium-high pressure for investigating the transient and time-averaged heat transfer of steam-water two-phase flow where the process involves the thermal oscillation. Non-dimensional parameters, the oscillatory frequency number Wo and oscillatory amplitude number Ap were used to characterize the effects of oscillation frequency and amplitude respectively, then a correlation was established based on the experimental data for predicting the time-averaged heat transfer coefficient under thermal oscillation condition.
| Original language | English |
|---|---|
| Pages (from-to) | 39-42 |
| Number of pages | 4 |
| Journal | Hsi-An Chiao Tung Ta Hsueh/Journal of Xi'an Jiaotong University |
| Volume | 33 |
| Issue number | 9 |
| State | Published - Sep 1999 |
Fingerprint
Dive into the research topics of 'Transient and time-averaged heat transfer of steam-water two-phase oscillatory flow in helical coiled tube of boiler reactor'. Together they form a unique fingerprint.Cite this