Skip to main navigation Skip to search Skip to main content

Time response of helium scintillation fission neutron detector

  • Xiaodong Zhang
  • , Mengtong Qiu
  • , Jianfu Zhang
  • , Xiaoping Ouyang
  • , Liang Chen
  • , Jinliang Liu
  • Northwest Institute of Nuclear Technology

Research output: Contribution to journal › Article › peer-review

Abstract

A new helium scintillation fission neutron detector was designed to detect the neutrons in the mixed pulse fission radiation field. The time response of the detector was investigated through theoretical and experimental methods. The flying time of the fragments and recoiled helium nucleus in helium scintillator were calculated based on the experimental formulae and method of Monte Carlo. The formula of detector's time response was deduced from the convolution method. The result of the calculating detector's wave indicated that the risetime was about 19.5 ns and FWHM was about 31.0 ns. The time response was measured on the dense plasma focus device (DPF) neutron generator. The theoretical results of time response were consistent with experimental results.

Original languageEnglish
Pages (from-to)1807-1811
Number of pages5
JournalQiangjiguang Yu Lizishu/High Power Laser and Particle Beams
Volume25
Issue number7
DOIs
StatePublished - Jul 2013
Externally publishedYes

Keywords

  • Detector
  • Flying time
  • Fragments
  • Helium scintillator
  • Time response

Fingerprint

Dive into the research topics of 'Time response of helium scintillation fission neutron detector'. Together they form a unique fingerprint.