Skip to main navigation Skip to search Skip to main content

Tibial post loading increases the risk of aseptic loosening of posterior-stabilized tibial prosthesis

  • Zhenxian Chen
  • , Jianian Han
  • , Jing Zhang
  • , Yinghu Peng
  • , Lei Guo
  • , Shibin Chen
  • , Zhongmin Jin
  • Chang'an University
  • Shenzhen Institute of Advanced Technology
  • University of Leeds
  • Southwest Jiaotong University

Research output: Contribution to journalArticlepeer-review

5 Scopus citations

Abstract

Aseptic loosening is the primary cause of failure following posterior-stabilized total knee arthroplasty. It is unclear whether tibial post loading of posterior-stabilized prosthesis increases the risk of aseptic loosening of the tibial prosthesis. The purpose of this study is to investigate the biomechanical effects of tibial post loading on the tibial prosthesis fixation interface during level walking, squatting, stair descent, and standing up-sitting down activities. In this paper, finite element models with and without post were established to compare the effects of tibial post loading on the von Mises stress of the proximal tibia, shear stress of the cement, and the bone-prosthesis interface micromotion during four physiological activities. The tibial post loading had an insignificant influence on tibial biomechanics and bone-prosthesis interface micromotion during leveling walking activity. However, compared to the insert without post condition, tibial post loading significantly increased the maximum tibial von Mises stress, the maximum shear stress in the medial of cement, and the bone-prosthesis interface peak micromotion by 912.84%, 612.77%, and 921.09%, respectively, at the moment of the maximum flexion angle for the stair descent activity, and 637.92%, 351.43%, and 519.13%, respectively, at the moment of the maximum flexion angle for the standing up-sitting down activity. Tibial post loading increased the risk of postoperative aseptic loosening of tibial prosthesis in patients with posterior-stabilized total knee arthroplasty, and it was recommended that the post-cam contact mechanism of posterior-stabilized prosthesis should be optimized to reduce the biomechanical impact of tibial post loading on tibial prosthesis fixation.

Original languageEnglish
Pages (from-to)886-896
Number of pages11
JournalProceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
Volume238
Issue number8-9
DOIs
StatePublished - 1 Aug 2024

Keywords

  • Total knee arthroplasty
  • bone-prosthesis interface micromotion
  • finite element analysis
  • posterior-stabilized prosthesis
  • stress distribution
  • tibial post loading

Fingerprint

Dive into the research topics of 'Tibial post loading increases the risk of aseptic loosening of posterior-stabilized tibial prosthesis'. Together they form a unique fingerprint.

Cite this