TY - JOUR
T1 - Thermodynamic analysis of a modified transcritical CO2 two-stage compression dual-temperature refrigeration cycle with an ejector
AU - Wen, Zhidong
AU - Bai, Tao
AU - Wan, Jiahao
N1 - Publisher Copyright:
© 2024 Elsevier Ltd
PY - 2024/12/1
Y1 - 2024/12/1
N2 - In this paper, a modified transcritical CO2 two-stage compression dual-temperature refrigeration cycle with an ejector is proposed. The thermodynamic analysis based on energy and exergy is conducted, discussing the effects of discharge pressure, gas cooler outlet temperature, evaporation temperature, and refrigeration capacity ratio. The particle swarm optimization algorithm is employed to determine the optimal discharge pressure. The results indicate that the modified cycle outperforms the basic cycle, achieving a maximum COP and exergy efficiency improvement of 24.76 % at the optimal discharge pressure. The maximum reduction in the high-pressure compressor discharge temperature is 24.95 °C, and the total compressor displacement decreases by up to 20.00 %. The performance enhancement of the ejector-enhanced cycle tends to be greater in the transcritical model compared to the subcritical model. Exergetic analysis reveals that the exergy destruction of the expansion device in the modified cycle is 22.9 kW, which is 37.38 % lower than that in the basic cycle, demonstrating the considerable expansion work recovery effect of the ejector. Finally, the correlation formula of the optimal high-pressure discharge pressure is fitted at the operating parameters.
AB - In this paper, a modified transcritical CO2 two-stage compression dual-temperature refrigeration cycle with an ejector is proposed. The thermodynamic analysis based on energy and exergy is conducted, discussing the effects of discharge pressure, gas cooler outlet temperature, evaporation temperature, and refrigeration capacity ratio. The particle swarm optimization algorithm is employed to determine the optimal discharge pressure. The results indicate that the modified cycle outperforms the basic cycle, achieving a maximum COP and exergy efficiency improvement of 24.76 % at the optimal discharge pressure. The maximum reduction in the high-pressure compressor discharge temperature is 24.95 °C, and the total compressor displacement decreases by up to 20.00 %. The performance enhancement of the ejector-enhanced cycle tends to be greater in the transcritical model compared to the subcritical model. Exergetic analysis reveals that the exergy destruction of the expansion device in the modified cycle is 22.9 kW, which is 37.38 % lower than that in the basic cycle, demonstrating the considerable expansion work recovery effect of the ejector. Finally, the correlation formula of the optimal high-pressure discharge pressure is fitted at the operating parameters.
KW - Ejector
KW - Performance improvement
KW - Thermodynamic analysis
KW - Transcritical CO refrigeration
KW - Two-stage compressor
UR - https://www.scopus.com/pages/publications/85203829774
U2 - 10.1016/j.applthermaleng.2024.124383
DO - 10.1016/j.applthermaleng.2024.124383
M3 - 文章
AN - SCOPUS:85203829774
SN - 1359-4311
VL - 257
JO - Applied Thermal Engineering
JF - Applied Thermal Engineering
M1 - 124383
ER -