T1 - Thermo-economic analysis on waste heat and water recovery systems of boiler exhaust in coal-fired power plants
AU - Yang, Kaixuan
AU - Liu, Ming
AU - Yan, Junjie
N1 - Publisher Copyright:
Copyright © 2020 ASME.
PY - 2020
Y1 - 2020
N2 - Waste heat and water recovery from boiler exhaust fluegas is significant for reducing coal and water consumption of coalfired power plants. In this study, waste heat and water recovery system No.1 (WHWR1) and No.2 (WHWR2) were proposed with a 330MW air-cooling coal-fired power plant as the reference power plant. In these systems, boiler exhaust fluegas is cooled to 95 °C in fluegas coolers before being fed to the electrostatic precipitator. Moreover, a fluegas condenser is installed after the desulfurizer to recover water from fluegas. The recovered waste heat is used to heat the condensation water of the regenerative system, boiler feeding air and the fluegas after fluegas condenser. Then, thermodynamic and economic analyses were carried out. Heat exchangers' areas of WHWRs are affected by heat loads and heat transfer temperature differences. For the unit area cost of heat exchangers is different, the cost of WHWRs may be decreased by optimizing multiple thermodynamic parameters of WHWR. Therefore, the optimization models based on Genetic Algorithm were developed to obtain the optimal system parameters with best economic performance. Results show that the change in coal consumption rate (Δb) is ∼ 4.8 g kW-1 h-1 in WHWR2 and ∼ 2.9 g kW-1 h-1 in WHWR1. About 15.3 kg s-1 of water can be saved and recovered when the fluegas moisture content is reduced to 8.5%. The investment of WHWR2 is higher than WHWR1, while the static recovery period of WHWR2 is shorter than that of WHWR1 for the additional Δb of pre air pre-heater.
AB - Waste heat and water recovery from boiler exhaust fluegas is significant for reducing coal and water consumption of coalfired power plants. In this study, waste heat and water recovery system No.1 (WHWR1) and No.2 (WHWR2) were proposed with a 330MW air-cooling coal-fired power plant as the reference power plant. In these systems, boiler exhaust fluegas is cooled to 95 °C in fluegas coolers before being fed to the electrostatic precipitator. Moreover, a fluegas condenser is installed after the desulfurizer to recover water from fluegas. The recovered waste heat is used to heat the condensation water of the regenerative system, boiler feeding air and the fluegas after fluegas condenser. Then, thermodynamic and economic analyses were carried out. Heat exchangers' areas of WHWRs are affected by heat loads and heat transfer temperature differences. For the unit area cost of heat exchangers is different, the cost of WHWRs may be decreased by optimizing multiple thermodynamic parameters of WHWR. Therefore, the optimization models based on Genetic Algorithm were developed to obtain the optimal system parameters with best economic performance. Results show that the change in coal consumption rate (Δb) is ∼ 4.8 g kW-1 h-1 in WHWR2 and ∼ 2.9 g kW-1 h-1 in WHWR1. About 15.3 kg s-1 of water can be saved and recovered when the fluegas moisture content is reduced to 8.5%. The investment of WHWR2 is higher than WHWR1, while the static recovery period of WHWR2 is shorter than that of WHWR1 for the additional Δb of pre air pre-heater.
KW - Fluegas
KW - Genetic algorithm
KW - Thermo-economic
KW - Water recovery
UR - https://www.scopus.com/pages/publications/85094186704
U2 - 10.1115/POWER2020-16269
DO - 10.1115/POWER2020-16269
M3 - 会议稿件
AN - SCOPUS:85094186704
T3 - American Society of Mechanical Engineers, Power Division (Publication) POWER
BT - ASME 2020 Power Conference, POWER 2020, collocated with the 2020 International Conference on Nuclear Engineering
PB - American Society of Mechanical Engineers (ASME)
T2 - 2019 Canadian Society for Civil Engineering Annual Conference, CSCE 2019
Y2 - 12 June 2019 through 15 June 2019
ER -