Skip to main navigation Skip to search Skip to main content

Theoretical investigation on the energetic and exergetic performance improvement method of the high temperature transcritical CO2 heat pump with two-stage expander

  • Liaoliang Jiang
  • , Tianliang Chang
  • , Shaoqiang Li
  • , Yulong Song
  • , Ce Cui
  • , Feng Cao
  • , Xiaolin Wang
  • School of Energy and Power Engineering
  • National Key Laboratory for High Energy Pulsed Power
  • University of Tasmania

Research output: Contribution to journal › Article › peer-review

Abstract

Coastal industries (e.g., food processing, chemical distillation), commercial facilities, and residential buildings demand high-temperature heat supply (90–140 °C). Conventional air-source heat pumps were limited to below 80 °C, while transcritical CO₂ seawater-source heat pumps offered a viable pathway by leveraging abundant seawater. However, existing systems suffered from suboptimal expansion work recovery and severe exergy destruction when the water outlet temperature exceeded 120 °C. This paper proposed a novel two-stage expander system (TSES) that closely matched the entire expansion process of the transcritical CO2 cycle, enabling efficient cascade energy recovery. Consequently, TSES overcame the operating range limitations of single-stage turbine system (STES) and single-stage volumetric expander systems (SVES). Thermodynamic modeling and performance comparisons demonstrated that TSES delivered clear advantages across typical seawater-source heating conditions. For instance, for gas-cooler inlet water temperatures between 35 °C and 60 °C, the heating coefficient of performance (COP) and exergy efficiency of the TSES consistently outperformed those of the single-stage expander systems by roughly 2%. Its relative improvement grew further with rising inlet water temperature, maintaining a lead of >8% over the reference systems at 60 °C. Furthermore, in the high-temperature heating region with gas-cooler outlet water temperature of 120–140 °C, the COP and exergy efficiency advantages of the TSES over the STES gradually widened from 2.71% to 6.27%, while its advantage over the SVES remained consistently above 8%. These gains stemmed from structural improvements: the TSES reduced the expansion exergy destruction share by over 30% and increased expansion work recovery rate by over 60% relative to both single-stage systems.

Original languageEnglish
Article number107093
JournalInternational Journal of Refrigeration
Volume191
DOIs
StatePublished - Nov 2026
Externally publishedYes

Keywords

  • Energy recovery
  • Exergy analysis
  • Inter-stage pressure
  • Seawater-source heat pump
  • Two-stage expander

Fingerprint

Dive into the research topics of 'Theoretical investigation on the energetic and exergetic performance improvement method of the high temperature transcritical CO2 heat pump with two-stage expander'. Together they form a unique fingerprint.

Cite this