Skip to main navigation Skip to search Skip to main content

The visualization study of breakup of drops in T-shaped micro-fluidic devices

  • Wei Meng Wang
  • , Yi Ping Ma
  • , Peng Wang
  • , Bin Chen
  • Xi'an Jiaotong University

Research output: Contribution to journal › Article › peer-review

3 Scopus citations

Abstract

In this paper, the experimental system was set up to study the symmetrical passive breakup of micro-droplet in T-shaped micro-fluidic chip. The process of the breakup of micro-droplet was observed and the mechanism was studied. In the experiment, the cross section of the micro-channel is 200 μm×100 μm or 100 μm×100 μm. Silicone oil and peanut oil were used as continuous phase, while deionized water was used as dispersed phase. For Ca number ranging from 0 to 0.1, four types of droplets' symmetrical breakup, breakup with tunnels, breakup with discontinuous obstruction, breakup with permanent wall obstruction, non-breakup were captured. Finally, the phase diagram was drawn and empirical correlations about critical Ca number and the non-dimensional length of micro-droplet were obtained to predict the conditions of weather the micro-droplet will breakup in different structure and sizes of micro-fluidic chips.

Original languageEnglish
Pages (from-to)338-341
Number of pages4
JournalKung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics
Volume36
Issue number2
StatePublished - 1 Feb 2015

Keywords

  • Flow visualization
  • Micro-droplet
  • Micro-fluidic chips
  • Passive breakup

Fingerprint

Dive into the research topics of 'The visualization study of breakup of drops in T-shaped micro-fluidic devices'. Together they form a unique fingerprint.

Cite this