Skip to main navigation Skip to search Skip to main content

The influence of splashing gold particles on vacuum flashover of unit crystal

  • Xi'an Jiaotong University

Research output: Contribution to journalArticlepeer-review

Abstract

The electrical strength of vacuum insulation system is usually limited by the flashover phenomenon across the surface of insulator in vacuum. The technology of splashing gold particles on unit crystal was adopted in this paper, and the flashover voltage of unit crystal in vacuum was found to increase obviously. Then SEEA theory was used to analyze and explain the reason of increasing insulation in vacuum.

Original languageEnglish
Pages (from-to)96-98
Number of pages3
JournalYadian Yu Shengguang/Piezoelectrics and Acoustooptics
Volume30
Issue numberSUPPL.
StatePublished - Jun 2008

Keywords

  • Flashover
  • Splash gold particle
  • Unit crystal
  • Vacuum

Fingerprint

Dive into the research topics of 'The influence of splashing gold particles on vacuum flashover of unit crystal'. Together they form a unique fingerprint.

Cite this