Skip to main navigation Skip to search Skip to main content

Textured-piezoelectric-ceramic-based focused intravascular ultrasonic transducer with improved image quality and uniformity

  • Chaorui Qiu
  • , Min Su
  • , Shuai Yang
  • , Baoqiang Liu
  • , Nanxiang Jia
  • , Zhuo Xu
  • , Hairong Zheng
  • , Lei Sun
  • , Weibao Qiu
  • , Fei Li
  • Xi'an Jiaotong University
  • Shenzhen Institute of Advanced Technology
  • Hong Kong Polytechnic University

Research output: Contribution to journal › Article › peer-review

2 Scopus citations

Abstract

Intravascular ultrasound (IVUS) imaging is a minimally invasive medical technology that plays a critical role in diagnosis, treatment guidance, and post-treatment assessment of coronary artery diseases. As a crucial component of the IVUS system, conventional IVUS transducers are designed to be planar and unfocused to adequately cover the region of interest. However, this design comes at the cost of spatial resolution. Here, we developed a high-performance focused IVUS transducer using Pb(In1/2Nb1/2)O3-Pb(Sc1/2Nb1/2)O3-PbTiO3 (PIN-PSN-PT) textured ceramics with both high electromechanical performance (thickness-mode electromechanical coupling factor kt: ∼60%) and high Curie temperature (TC: ∼250 °C). Benefiting from the relatively low clamped dielectric constant ( ϵ 33 S /ϵ0: ∼450) of PIN-PSN-PT-textured ceramics in contrast to currently used soft piezoelectric ceramics (>1000), we designed a relatively large aperture for the focused IVUS transducer, with a goal of enhancing lateral resolution across a larger depth of field, ranging from 1 to 5 mm. The developed focused IVUS transducer operates at 42 MHz with an −6 dB bandwidth of 72%, featuring a 0.6 × 0.6 mm2 aperture while maintaining an electrical impedance of approximately 40-60 Ω. The axial and lateral resolutions characterized by wire phantom imaging are 45 and 208 μm, respectively. The acoustic pressure generated by the focused IVUS transducer is 1.4 times higher than that of its planar counterpart. Ex vivo porcine coronary artery imaging demonstrates that our focused IVUS transducer offers improved image quality and uniformity for the visualization of intravascular structures. Our work shows great potential of PIN-PSN-PT-textured ceramics for creating high-frequency miniaturized focused transducers.

Original languageEnglish
Article number232901
JournalApplied Physics Letters
Volume125
Issue number23
DOIs
StatePublished - 2 Dec 2024

Fingerprint

Dive into the research topics of 'Textured-piezoelectric-ceramic-based focused intravascular ultrasonic transducer with improved image quality and uniformity'. Together they form a unique fingerprint.

Cite this