Skip to main navigation Skip to search Skip to main content

Sulfuric acid deposition characteristics of H-type finned tube bank with 10 rows

  • Xi'an Jiaotong University

Research output: Contribution to journalArticlepeer-review

45 Scopus citations

Abstract

The deposition rate and condensate mass fraction of sulfuric acid on heat exchanger surfaces play a decisive role on the local low-temperature corrosion of heat exchangers. Based on the prediction model of acid deposition, a three-dimensional numerical simulation was performed for acid deposition characteristics of H-type finned tube bank with 10 rows. The effect of six geometric parameters (spanwise tube pitch, longitudinal tube pitch, fin height, fin pitch, fin thickness and slit width) and Reynolds number are examined. It can be observed that the fin thickness and Reynolds number have the most significant effect on acid deposition. A large fin thickness will greatly increase the risks of fin corrosion, and it is not recommended for practical use. According to the calculation results, a correlation of Sh number of sulfuric acid vs fin geometries for the 10-row tube bundle is presented.

Original languageEnglish
Pages (from-to)137-141
Number of pages5
JournalInternational Journal of Heat and Mass Transfer
Volume81
DOIs
StatePublished - Feb 2015

Keywords

  • Deposition
  • H-type finned tube
  • Heat exchanger
  • Waste heat recovery

Fingerprint

Dive into the research topics of 'Sulfuric acid deposition characteristics of H-type finned tube bank with 10 rows'. Together they form a unique fingerprint.

Cite this