Skip to main navigation Skip to search Skip to main content

Study on steady natural circulation capacity of CARR

  • Xi'an Jiaotong University
  • China National Nuclear Corporation

Research output: Contribution to journal › Article › peer-review

5 Scopus citations

Abstract

An analysis code was developed to calculate the natural circulation capacity of China Advanced Research Reactor (CARR) under the conditions of different pool water temperatures. The influence of the pool water temperature on natural circulation characteristics was analyzed, and it was showed that the natural circulation flow rate increased however, the natural circulation capacity decreased with the increasing pool water temperature. Based on the computational result and the theoretical deduction, a correlation was proposed to predicting the relationship between the natural circulation mass flow and the core power under different conditions. The correlation prediction agreed well with the computational result, and the maximal error was less than ±10%.

Original languageEnglish
Pages (from-to)13-18
Number of pages6
JournalHedongli Gongcheng/Nuclear Power Engineering
Volume28
Issue number2
StatePublished - Apr 2007

Keywords

  • China Advanced Research Reactor
  • Natural circulation capacity
  • Steady state characteristic

Fingerprint

Dive into the research topics of 'Study on steady natural circulation capacity of CARR'. Together they form a unique fingerprint.

Cite this