TY - GEN
T1 - Study on inter-harmonics in short-circuit current of hybrid AC/DC electric power systems
AU - He, Jian
AU - Liu, Jun
AU - Hao, Xudong
AU - Wang, Xu
AU - Zhang, Xudong
N1 - Publisher Copyright:
© 2016 IEEE.
PY - 2016/9/23
Y1 - 2016/9/23
N2 - With the widespread application of HVDC technology, power system harmonics generated by power electronic equipments can no longer be neglected. For example, the real-time current signal processing for protective relays or PMUs might be deeply affected by harmonics. In order to tackle with the accuracy for relays and PMUs, the inter-harmonic source for short-circuit current is theoretically analyzed, based on the interactions between low frequency oscillations in the power system electromechanical stability area and the electromagnetic transient process during faults. A typical hybrid AC/DC system is modeled and simulated, quantitative analyses on the inter-harmonic components in short-circuit current waveform are conducted with 51Hz and 52.5Hz simulated low frequency oscillation AC sources separately. The inter-harmonic phenomenon in transient short-circuit current is demonstrated by the simulation results, and it is suggested that the influence of inter-harmonic should not be neglected during online real-time signal processing of protective relays or PMUs.
AB - With the widespread application of HVDC technology, power system harmonics generated by power electronic equipments can no longer be neglected. For example, the real-time current signal processing for protective relays or PMUs might be deeply affected by harmonics. In order to tackle with the accuracy for relays and PMUs, the inter-harmonic source for short-circuit current is theoretically analyzed, based on the interactions between low frequency oscillations in the power system electromechanical stability area and the electromagnetic transient process during faults. A typical hybrid AC/DC system is modeled and simulated, quantitative analyses on the inter-harmonic components in short-circuit current waveform are conducted with 51Hz and 52.5Hz simulated low frequency oscillation AC sources separately. The inter-harmonic phenomenon in transient short-circuit current is demonstrated by the simulation results, and it is suggested that the influence of inter-harmonic should not be neglected during online real-time signal processing of protective relays or PMUs.
KW - Hybrid AC-DC System
KW - Inter-harmonics
KW - Low Frequency Oscillation
KW - Short-Circuit Current
UR - https://www.scopus.com/pages/publications/84990985704
U2 - 10.1109/CICED.2016.7576162
DO - 10.1109/CICED.2016.7576162
M3 - 会议稿件
AN - SCOPUS:84990985704
T3 - China International Conference on Electricity Distribution, CICED
BT - 2016 China International Conference on Electricity Distribution, CICED 2016 - Proceedings
PB - IEEE Computer Society
T2 - 2016 China International Conference on Electricity Distribution, CICED 2016
Y2 - 10 August 2016 through 13 August 2016
ER -