Skip to main navigation Skip to search Skip to main content

Study on dryout point in vertical narrow annuli

  • Xi'an Jiaotong University

Research output: Contribution to journal › Article › peer-review

7 Scopus citations

Abstract

Prediction of dryout point is experimentally investigated with deionized water upflowing through narrow annular channel with 1.0 mm and 1.5 mm gap respectively. The annulus with narrow gap is bilaterally heated by AC current power supply. The experimental conditions covered a range of pressure from 0.8 to 3.5 MPa, mass flux of 26.6 to 68.8 kg·m-2·s-1 and wall heat flux of 5 to 50 kW·m-2. The location of dryout is obtained by observing a sudden rise in surface temperature. Kutateladze correlation is cited and modified to predict the location of dryout and proved to be not a proper one. Considering in detail the effects of geometry of annuli, pressure, mass flux and heat flux on dryout, an empirical correction is finally developed to predict dryout point in narrow annular gap under low How condition, which has a good agreement with experimental data.

Original languageEnglish
Pages (from-to)53-58
Number of pages6
JournalNuclear Science and Techniques
Volume16
Issue number1
StatePublished - Feb 2005

Keywords

  • Annular flow
  • Bilaterally heating
  • Critical quality
  • Dryout point
  • Narrow annular channel

Fingerprint

Dive into the research topics of 'Study on dryout point in vertical narrow annuli'. Together they form a unique fingerprint.