Abstract
Cold-chain transport has been suggested to be an important means for the cross-regional transmission of pathogenic microorganisms. In this study, NO x mode and O3 mode air discharges were combined by mixing effluent gases for sterilization in several cold-chain environments. It was found that the mixed gas effectively inactivated Salmonella typhimurium and Staphylococcus aureus in 1-4 mm thick ice layers at different temperatures (−20/−40/−80 °C) within 10 min, which is a significantly stronger effect than that of the effluent gas of either the NO x mode or the O3 mode discharge alone. This can be attributed to the high-valence reactive nitrogen species such as N2O5. Our findings provide a promising sterilization strategy to curb the spread of infectious diseases in cold-chain environments.
| Original language | English |
|---|---|
| Article number | 125006 |
| Journal | Plasma Sources Science and Technology |
| Volume | 31 |
| Issue number | 12 |
| DOIs | |
| State | Published - Dec 2022 |
UN SDGs
This output contributes to the following UN Sustainable Development Goals (SDGs)
-
SDG 3 Good Health and Well-being
Keywords
- cold-chain environment
- discharge mode
- reactive species
- sterilization effect
Fingerprint
Dive into the research topics of 'Sterilization of Salmonella typhimurium and Staphylococcus aureus in different cold-chain environments by combining NO x mode and O3 mode air discharges'. Together they form a unique fingerprint.Cite this