Stability analysis of single-phase grid-connected inverter with L-filter

  • Ruiliang Xie
  • , Xiang Hao
  • , Xu Yang
  • , Lang Huang
  • , Chao Wang
  • , Yuehong Yang
  • Xi'an Jiaotong University

Research output: Chapter in Book/Report/Conference proceedingConference contributionpeer-review

3 Scopus citations

Abstract

As an important part of the distributed power generation system, grid-connected inverter has been widely used. However, as a time-varying nonlinear system, the grid-connected inverter has complex dynamic behavior, which can cause serious stability problem. As a consequence, more and more researches have focused on this issue, most of which are limited to the stability problem caused by the variations of controller parameters, input voltage or load. This paper analyzes respectively the factors that may lead to instability such as harmonic voltage amplitude, harmonic voltage order, inductor saturation and dead-time nonlinearity. The analysis result shows that the harmonic voltage will not influence the stability of the system, but the inductor saturation and dead-time effect will cause serious stability problem in some cases. Furthermore, the design references of the controller parameters are proposed based on the result of stability analysis, which supplements the existing design references.

Original languageEnglish
Title of host publication2014 IEEE Energy Conversion Congress and Exposition, ECCE 2014
PublisherInstitute of Electrical and Electronics Engineers Inc.
Pages5626-5630
Number of pages5
ISBN (Electronic)9781479956982
DOIs
StatePublished - 11 Nov 2014

Publication series

Name2014 IEEE Energy Conversion Congress and Exposition, ECCE 2014

Fingerprint

Dive into the research topics of 'Stability analysis of single-phase grid-connected inverter with L-filter'. Together they form a unique fingerprint.

Cite this