T1 - Stability analysis of single-phase grid-connected inverter with L-filter
AU - Xie, Ruiliang
AU - Hao, Xiang
AU - Yang, Xu
AU - Huang, Lang
AU - Wang, Chao
AU - Yang, Yuehong
N1 - Publisher Copyright:
© 2014 IEEE.
PY - 2014/11/11
Y1 - 2014/11/11
N2 - As an important part of the distributed power generation system, grid-connected inverter has been widely used. However, as a time-varying nonlinear system, the grid-connected inverter has complex dynamic behavior, which can cause serious stability problem. As a consequence, more and more researches have focused on this issue, most of which are limited to the stability problem caused by the variations of controller parameters, input voltage or load. This paper analyzes respectively the factors that may lead to instability such as harmonic voltage amplitude, harmonic voltage order, inductor saturation and dead-time nonlinearity. The analysis result shows that the harmonic voltage will not influence the stability of the system, but the inductor saturation and dead-time effect will cause serious stability problem in some cases. Furthermore, the design references of the controller parameters are proposed based on the result of stability analysis, which supplements the existing design references.
AB - As an important part of the distributed power generation system, grid-connected inverter has been widely used. However, as a time-varying nonlinear system, the grid-connected inverter has complex dynamic behavior, which can cause serious stability problem. As a consequence, more and more researches have focused on this issue, most of which are limited to the stability problem caused by the variations of controller parameters, input voltage or load. This paper analyzes respectively the factors that may lead to instability such as harmonic voltage amplitude, harmonic voltage order, inductor saturation and dead-time nonlinearity. The analysis result shows that the harmonic voltage will not influence the stability of the system, but the inductor saturation and dead-time effect will cause serious stability problem in some cases. Furthermore, the design references of the controller parameters are proposed based on the result of stability analysis, which supplements the existing design references.
UR - https://www.scopus.com/pages/publications/84934324305
U2 - 10.1109/ECCE.2014.6954172
DO - 10.1109/ECCE.2014.6954172
M3 - 会议稿件
AN - SCOPUS:84934324305
T3 - 2014 IEEE Energy Conversion Congress and Exposition, ECCE 2014
SP - 5626
EP - 5630
BT - 2014 IEEE Energy Conversion Congress and Exposition, ECCE 2014
PB - Institute of Electrical and Electronics Engineers Inc.
ER -