Skip to main navigation Skip to search Skip to main content

Simultaneous determination of Cu2+, Zn2+ and Fe2+ by low pressure ion chromatography in water

  • Zhao Li Wang
  • , Xin Shen Zhang
  • , Ya Jun Luo
  • , Xiao Ping Jiang
  • Sichuan University

Research output: Contribution to journal › Article › peer-review

Abstract

A simple, rapid and accurate quantitative method for the determination of copper, zinc and iron in water by visual photometric low pressure ion chromatography was described. The analysis was performed with a low pressure cation column. The eluent is 40 mmol/L tartaric acid and 20 mmol/1 citric acid (pH4.30). The detection limits for copper, zinc and iron are 0.05 μg/ml, 0.05 μg/ml and 0.06 μg/ml, repectively. The method was used to determine copper, zinc and iron in water samples with satisfactory results. The recoveries for copper., zinc and iron are 99.0%-102.0%, 97.0%-104.0%, 98.0%-104.0%, respectively.

Original languageEnglish
Pages (from-to)50-52
Number of pages3
JournalSichuan Daxue Xuebao (Gongcheng Kexue Ban)/Journal of Sichuan University (Engineering Science Edition)
Volume36
Issue number4
StatePublished - Jul 2004
Externally publishedYes

Keywords

  • Copper
  • Iron
  • Low pressure cation column
  • Low pressure ion chromatography
  • Zinc

Fingerprint

Dive into the research topics of 'Simultaneous determination of Cu2+, Zn2+ and Fe2+ by low pressure ion chromatography in water'. Together they form a unique fingerprint.

Cite this