Skip to main navigation Skip to search Skip to main content

Robust dynamic myocardial perfusion CT deconvolution for accurate residue function estimation via adaptive-weighted tensor total variation regularization: A preclinical study

  • Dong Zeng
  • , Changfei Gong
  • , Zhaoying Bian
  • , Jing Huang
  • , Xinyu Zhang
  • , Hua Zhang
  • , Lijun Lu
  • , Shanzhou Niu
  • , Zhang Zhang
  • , Zhengrong Liang
  • , Qianjin Feng
  • , Wufan Chen
  • , Jianhua Ma
  • Southern Medical University
  • Gannan Normal University
  • Tianjin Medical University
  • Stony Brook University

Research output: Contribution to journalArticlepeer-review

12 Scopus citations

Abstract

Dynamic myocardial perfusion computed tomography (MPCT) is a promising technique for quick diagnosis and risk stratification of coronary artery disease. However, one major drawback of dynamic MPCT imaging is the heavy radiation dose to patients due to its dynamic image acquisition protocol. In this work, to address this issue, we present a robust dynamic MPCT deconvolution algorithm via adaptive-weighted tensor total variation (AwTTV) regularization for accurate residue function estimation with low-mA s data acquisitions. For simplicity, the presented method is termed 'MPD-AwTTV'. More specifically, the gains of the AwTTV regularization over the original tensor total variation regularization are from the anisotropic edge property of the sequential MPCT images. To minimize the associative objective function we propose an efficient iterative optimization strategy with fast convergence rate in the framework of an iterative shrinkage/thresholding algorithm. We validate and evaluate the presented algorithm using both digital XCAT phantom and preclinical porcine data. The preliminary experimental results have demonstrated that the presented MPD-AwTTV deconvolution algorithm can achieve remarkable gains in noise-induced artifact suppression, edge detail preservation, and accurate flow-scaled residue function and MPHM estimation as compared with the other existing deconvolution algorithms in digital phantom studies, and similar gains can be obtained in the porcine data experiment.

Original languageEnglish
Pages (from-to)8135-8156
Number of pages22
JournalPhysics in Medicine and Biology
Volume61
Issue number22
DOIs
StatePublished - 26 Oct 2016
Externally publishedYes

Keywords

  • adaptive-weighted tensor total variation regularization
  • deconvolution
  • flow-scaled residue function
  • low mA s
  • myocardial perfusion computed tomography

Fingerprint