Skip to main navigation Skip to search Skip to main content

Research on the pressure-lifting performance calculation model of supersonic steam-water two-phase flow in channel of variable section

  • Yang Peng He
  • , Jun Jie Yan
  • , Ji Ping Liu
  • , Fu Yu Zhao
  • , Wan Chao Lin
  • Xi'an Jiaotong University

Research output: Contribution to journalArticlepeer-review

1 Scopus citations

Abstract

According to the experiment results of steam-water two-phase flow in variable channel (steam injector), the relationships among the outlet pressure of water nozzle and the inlet low-pressure water temperature, flow flux, or the water temperature rise are quantitatively studied. The mathematical formula for the outlet pressure of water nozzle is obtained. Then the pressure-lifting performance calculation model of supersonic steam-water two-phase flow in variable channel is developed. The error between the calculation result using this model and the experiment result is less than 10%. These are beneficial to the development of the lifting pressure technology with supersonic two-phase flow in channel of variable section.

Original languageEnglish
Pages (from-to)113-117
Number of pages5
JournalHedongli Gongcheng/Nuclear Power Engineering
Volume25
Issue number2
StatePublished - Apr 2004

Keywords

  • Injection
  • Lifting pressure
  • Supersonic
  • Two-phase flow

Fingerprint

Dive into the research topics of 'Research on the pressure-lifting performance calculation model of supersonic steam-water two-phase flow in channel of variable section'. Together they form a unique fingerprint.

Cite this