Replacing true unenhanced imaging in renal carcinoma with virtual unenhanced images in dual-energy spectral CT: a feasibility study

  • G. Ma
  • , D. Han
  • , S. Dang
  • , N. Yu
  • , Q. Yang
  • , C. Yang
  • , C. Jin
  • , Y. Dou
  • Shaanxi University of Chinese Medicine
  • The First Affiliated Hospital of Xi’an Jiaotong University

Research output: Contribution to journalArticlepeer-review

19 Scopus citations

Abstract

Aim: To investigate the clinical value of virtual unenhanced (VNC) spectral computed tomography (CT) images to replace the conventional true unenhanced spectral CT images (TNC) in diagnosing renal carcinoma. Materials and methods: Fifty-six cases of renal carcinoma confirmed by histopathology underwent conventional plain CT and contrast-enhanced spectral CT at arterial phase (AP) and venous phase (VP). VNC images were generated on an AW4.6 workstation. The CT attenuation, image noise, contrast-to-noise ratio (CNR), and signal-noise-ratio (SNR) of the renal lesions and normal kidneys, long and short axis diameters of the lesion were measured from the three image sets and analysed using one-way analysis of variance (ANOVA). Two radiologists evaluated image quality subjectively using a five-point score, and lesion signature using a three-point score. Image quality scores were compared statistically and tested for consistency. Results: The two reviewers had good agreement for subjective evaluation (Kappa>0.70) and there was no difference in the quality of the scores among the three image groups. The lesion signature scores were all above the acceptable level. The CNR and SNR values in VNC were significantly higher than in TNC (p<0.05). VNC images had lower renal noise than in TNC (p<0.05). There was no difference in the long and short axis diameters of the lesion among the three image groups. VNC had higher CT attenuation values for the lesion and kidney than TNC (p<0.05), but the differences were <5 HU. Conclusion: VNC images in spectral CT may be used to replace the conventional plain CT to reduce imaging duration and radiation dose in diagnosing renal carcinoma.

Original languageEnglish
Pages (from-to)81.e21-81.e27
JournalClinical Radiology
Volume76
Issue number1
DOIs
StatePublished - Jan 2021
Externally publishedYes

Fingerprint

Dive into the research topics of 'Replacing true unenhanced imaging in renal carcinoma with virtual unenhanced images in dual-energy spectral CT: a feasibility study'. Together they form a unique fingerprint.

Cite this