Skip to main navigation Skip to search Skip to main content

Reliable Detection Method of Variable Series Arc Fault in Building Integrated Photovoltaic Systems Based on Nonstationary Time Series Analysis

  • Silei Chen
  • , Hancong Wu
  • , Yu Meng
  • , Yuanfeng Wang
  • , Xingwen Li
  • , Chenjia Zhang
  • Xi'an University of Technology
  • Xi'an Jiaotong University

Research output: Contribution to journalArticlepeer-review

24 Scopus citations

Abstract

Arc fault characteristics would be influenced by diverse system elements and operation levels in building integrated photovoltaic (BIPV) systems, which would challenge the arc fault detection. This article aims at improving the detection reliability and speed by applying the time series analysis at feature and classification layers to reflect the random evolution process of arc fault current. According to the arc ignition method in UL1699B, arc fault signals are first sampled with a residential storage element and ten dc load elements at three voltage levels in BIPV systems. After evaluating time-frequency information with established indexes, variable and early arc fault are discovered to have no obvious current and harmonic indications due to strong system element noises, sensor precision, and low arc energy. Then, the sample entropy (SE) feature and gated recurrent unit (GRU) classifier are proposed to improve the detection performance through involving the nonstationary time series correlation of the arc fault current. An arc fault simulation platform is built to generate arc current with low signal-to-noise ratio (SNR), which proves the detection algorithm integrates multisource information to grasp the appearance of new signal pattern. Next, constrained optimization problems are designed for both feature and classifier layers to achieve the most distinguishable arc fault and fault-like performance. With matched optimization methods, the modified SE and GRU method could improve the detection accuracy by an average of 21.08% after comparing with existing features and classifiers. Finally, hardware implementation results indicate a higher detection accuracy and less runtime of the proposed detection method.

Original languageEnglish
Pages (from-to)8654-8664
Number of pages11
JournalIEEE Sensors Journal
Volume23
Issue number8
DOIs
StatePublished - 15 Apr 2023

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 7 - Affordable and Clean Energy
    SDG 7 Affordable and Clean Energy

Keywords

  • Atypical series arc fault
  • building integrated photovoltaic (BIPV) systems
  • nonstationary time series analysis
  • parameter match
  • time - frequency characteristics

Fingerprint

Dive into the research topics of 'Reliable Detection Method of Variable Series Arc Fault in Building Integrated Photovoltaic Systems Based on Nonstationary Time Series Analysis'. Together they form a unique fingerprint.

Cite this