TY - GEN
T1 - Quantitative detection of Escherichia coli and measurement of urinary tract infection diagnosis possibility by use of a portable, handheld sensor
AU - Feng, Shilun
AU - Roseng, Lars Eric
AU - Dong, Tao
N1 - Publisher Copyright:
© 2015 IEEE.
PY - 2015/6/30
Y1 - 2015/6/30
N2 - Electrochemical nitrite sensor was used to quantitatively detect the nitrite concentration in urine and by building the approximate relationship between the nitrite concentration and number of E.coli bacterias, electrochemical nitrite sensor can count the numbers of Escherichia coli and do the Urinary Tract Infection (UTI) Diagnosis. Electrochemical nitrite sensor was assembled and calibrated, the artificial urine sample was detected; the feasibility of electrochemical nitrite sensor including the errors effect had been checked and proved at around-5.1∼2.3%; the possibility to detect artificial UTI urine sample out is around 95.5%; the approximate relationship between the number of E.coli and electrode potential had been built as E=228.3193-3.78225×Ln (N+2.29101e6), thereby building the relationship between UTI possibilities and the measurement. Finally, the conception and design of electrochemical sensor array had been made, thus to measure different biomarkers for the maximum possibilities of UTI and can show the data of the possibility of UTI directly on the screen. Furthermore, it can easily be used and transported for the home-users or patients in hospitals.
AB - Electrochemical nitrite sensor was used to quantitatively detect the nitrite concentration in urine and by building the approximate relationship between the nitrite concentration and number of E.coli bacterias, electrochemical nitrite sensor can count the numbers of Escherichia coli and do the Urinary Tract Infection (UTI) Diagnosis. Electrochemical nitrite sensor was assembled and calibrated, the artificial urine sample was detected; the feasibility of electrochemical nitrite sensor including the errors effect had been checked and proved at around-5.1∼2.3%; the possibility to detect artificial UTI urine sample out is around 95.5%; the approximate relationship between the number of E.coli and electrode potential had been built as E=228.3193-3.78225×Ln (N+2.29101e6), thereby building the relationship between UTI possibilities and the measurement. Finally, the conception and design of electrochemical sensor array had been made, thus to measure different biomarkers for the maximum possibilities of UTI and can show the data of the possibility of UTI directly on the screen. Furthermore, it can easily be used and transported for the home-users or patients in hospitals.
KW - Electrochemical sensor
KW - Escherichia coli bacteria
KW - Nitrite
KW - Urinary Tract Infection
UR - https://www.scopus.com/pages/publications/84939558363
U2 - 10.1109/MeMeA.2015.7145271
DO - 10.1109/MeMeA.2015.7145271
M3 - 会议稿件
AN - SCOPUS:84939558363
T3 - 2015 IEEE International Symposium on Medical Measurements and Applications, MeMeA 2015 - Proceedings
SP - 586
EP - 589
BT - 2015 IEEE International Symposium on Medical Measurements and Applications, MeMeA 2015 - Proceedings
PB - Institute of Electrical and Electronics Engineers Inc.
T2 - 2015 IEEE International Symposium on Medical Measurements and Applications, MeMeA 2015
Y2 - 7 May 2015 through 9 May 2015
ER -