Abstract
The paper describes our research on infrared-sensitive streak camera that adopts a streak tube with a complex photocathode which consists of a membrane made of up-converting material (one kind of ET material) and a S-20 photocathode. The up-converting screen is able to convert 800nm-1600nm infrared radiation to visible light. The peak values of the converting efficiency are located at 1165nm.for CaS:Eu, Sm and 1060nm for CaS:Ce, Sm. We obtained a novel result of time resolution of the ET-materials and the streak camera attains time resolution of 12.3ps for CaS:Eu, Sm screen and 8.4ps for CaS:Ce, Sm screen.
| Original language | English |
|---|---|
| Pages (from-to) | 160-166 |
| Number of pages | 7 |
| Journal | Proceedings of SPIE - The International Society for Optical Engineering |
| Volume | 3516 |
| Issue number | I |
| State | Published - 1999 |
| Externally published | Yes |
| Event | Proceedings of the 1998 23rd International Congress on High-Speed Photography and Photonics (ICHSPP-98) - Moscow, Russia Duration: 20 Sep 1998 → 25 Sep 1998 |