TY - JOUR
T1 - Promote quantitative ischemia imaging via myocardial perfusion CT iterative reconstruction with tensor total generalized variation regularization
AU - Gu, Chengwei
AU - Zeng, Dong
AU - Lin, Jiahui
AU - Li, Sui
AU - He, Ji
AU - Zhang, Hao
AU - Bian, Zhaoying
AU - Niu, Shanzhou
AU - Zhang, Zhang
AU - Huang, Jing
AU - Chen, Bo
AU - Zhao, Dazhe
AU - Chen, Wufan
AU - Ma, Jianhua
N1 - Publisher Copyright:
© 2018 Institute of Physics and Engineering in Medicine.
PY - 2018/6/12
Y1 - 2018/6/12
N2 - Myocardial perfusion computed tomography (MPCT) imaging is commonly used to detect myocardial ischemia quantitatively. A limitation in MPCT is that an additional radiation dose is required compared to unenhanced CT due to its repeated dynamic data acquisition. Meanwhile, noise and streak artifacts in low-dose cases are the main factors that degrade the accuracy of quantifying myocardial ischemia and hamper the diagnostic utility of the filtered backprojection reconstructed MPCT images. Moreover, it is noted that the MPCT images are composed of a series of 2/3D images, which can be naturally regarded as a 3/4-order tensor, and the MPCT images are globally correlated along time and are sparse across space. To obtain higher fidelity ischemia from low-dose MPCT acquisitions quantitatively, we propose a robust statistical iterative MPCT image reconstruction algorithm by incorporating tensor total generalized variation (TTGV) regularization into a penalized weighted least-squares framework. Specifically, the TTGV regularization fuses the spatial correlation of the myocardial structure and the temporal continuation of the contrast agent intake during the perfusion. Then, an efficient iterative strategy is developed for the objective function optimization. Comprehensive evaluations have been conducted on a digital XCAT phantom and a preclinical porcine dataset regarding the accuracy of the reconstructed MPCT images, the quantitative differentiation of ischemia and the algorithm's robustness and efficiency.
AB - Myocardial perfusion computed tomography (MPCT) imaging is commonly used to detect myocardial ischemia quantitatively. A limitation in MPCT is that an additional radiation dose is required compared to unenhanced CT due to its repeated dynamic data acquisition. Meanwhile, noise and streak artifacts in low-dose cases are the main factors that degrade the accuracy of quantifying myocardial ischemia and hamper the diagnostic utility of the filtered backprojection reconstructed MPCT images. Moreover, it is noted that the MPCT images are composed of a series of 2/3D images, which can be naturally regarded as a 3/4-order tensor, and the MPCT images are globally correlated along time and are sparse across space. To obtain higher fidelity ischemia from low-dose MPCT acquisitions quantitatively, we propose a robust statistical iterative MPCT image reconstruction algorithm by incorporating tensor total generalized variation (TTGV) regularization into a penalized weighted least-squares framework. Specifically, the TTGV regularization fuses the spatial correlation of the myocardial structure and the temporal continuation of the contrast agent intake during the perfusion. Then, an efficient iterative strategy is developed for the objective function optimization. Comprehensive evaluations have been conducted on a digital XCAT phantom and a preclinical porcine dataset regarding the accuracy of the reconstructed MPCT images, the quantitative differentiation of ischemia and the algorithm's robustness and efficiency.
KW - low-dose
KW - myocardial perfusion computed tomography
KW - quantify myocardial ischemia
KW - regularization
KW - tensor total generalized variation
UR - https://www.scopus.com/pages/publications/85049373451
U2 - 10.1088/1361-6560/aac7bd
DO - 10.1088/1361-6560/aac7bd
M3 - 文章
C2 - 29794346
AN - SCOPUS:85049373451
SN - 0031-9155
VL - 63
JO - Physics in Medicine and Biology
JF - Physics in Medicine and Biology
IS - 12
M1 - 125009
ER -