Abstract
This paper describes the structures of the ±100kV multi gap multi channel gas switch. The self breakdown performance of ten switches is introduced. A test bed for synchronous discharge is established. Ten switches are arranged in parallel, and then the synchronous discharge is carried out. The cases with different switching coefficients are analyzed. Two types of trigger isolating water resistors are used in the test. The experimental result indicates that 110kA output current with 100ns rise time can be achieved when the switches are filled with 0.16MPa nitrogen, and charged to ±65kV.
| Original language | English |
|---|---|
| State | Published - 2008 |
| Externally published | Yes |
| Event | 17th International Conference on High Power Particle Beams, BEAMS'08 - Xi'an, China Duration: 6 Jul 2008 → 11 Jul 2008 |
Conference
| Conference | 17th International Conference on High Power Particle Beams, BEAMS'08 |
|---|---|
| Country/Territory | China |
| City | Xi'an |
| Period | 6/07/08 → 11/07/08 |
Keywords
- Gas switch
- Multi gap multi channel
- Pulsed power
- Synchronous discharge
- linear transformer driver
Fingerprint
Dive into the research topics of 'Primary experimental study on synchronous discharge of ten multi gap multi channel gas switches'. Together they form a unique fingerprint.Cite this