Abstract
Using grey systems theory and experimental data obtained from sodium boiling test loop in China, the grey mutual analysis of some parameters influencing sodium CHF is carried out, and the CHF values are predicted by GM(1,1) model. The GM (1,h) model is established for CHF prediction, and the predicted CHF values are in good agreement with the experimental data.
| Original language | English |
|---|---|
| Pages (from-to) | 27-33 |
| Number of pages | 7 |
| Journal | Yuanzineng Kexue Jishu/Atomic Energy Science and Technology |
| Volume | 35 |
| Issue number | 1 |
| State | Published - Jan 2001 |
Keywords
- Critical heat flux
- Grey systems theory
- Liquid sodium