Abstract
Static CT imaging requires a compact X-ray source capable of spatially addressable emission without mechanical motion while maintaining stable spectral characteristics. Here, we develop a vacuum-sealed planar-gate ZnO nanowire cold cathode flat panel X-ray source (FPXS) that enables 32 independently addressable emission units. Experimentally, unit-selective luminescence imaging and anode current-gate voltage (Ia-Vg) characteristics showing a monotonic increase verify a reliable gate-controlled addressing function. The device achieves a maximum Ia of 46.3 μA and an X-ray dose rate of 57.8 μGy/s from four addressable units. In addition, unit-by-unit addressable projection imaging is demonstrated, and preliminary tomosynthesis reconstruction using the coded array beam X-ray imaging (CABI) algorithm shows that structural details can be recovered from the addressed projection data. This work establishes a planar-gate cold cathode FPXS imaging installation for encodable X-ray generation by gate driving and highlights its potential for high-speed, high-resolution static CT imaging.
| Original language | English |
|---|---|
| Article number | 168323 |
| Journal | Applied Surface Science |
| Volume | 752 |
| DOIs | |
| State | Published - 15 Jan 2027 |
Keywords
- Cold cathode
- Field emission
- Planar gate
- Tomosynthesis imaging
- ZnO nanowires
Fingerprint
Dive into the research topics of 'Planar-gate zinc oxide nanowire cold cathode flat-panel X-ray source for tomosynthesis imaging'. Together they form a unique fingerprint.Cite this