@inproceedings{9f219cd2ce7f449ba6a9aec298a7d134,
title = "Pirani gauge based hermeticity monitoring for un-cooled micro bolometer array",
abstract = "This paper presents a novel method to analyze the thermal conductance under vacuum environment for MEMS devices. The Si/Ge-based Pirani gauge introduced is developed for monitoring the package hermeticity of MEMS Bolometer array, which has the total same structure as the single bolometer pixel for the characteristic of functional material. Meanwhile the 'Extended Fourier's Law' is verified by free molecular theory and is applied into the thermal analysis of the micro-structure under the pressure below 100Pa. Thermal interaction between Focus Plane Arrays (FPAs) and Pirani gauge is checked to guarantee the normal performance as the influence from each side are under 2X lO-3K, which is acceptable for the products. This design can save the cost in fabrication significantly due to no extra process flow. The commercial value is affirmed by industry partner.",
author = "Dong Tao and Xiao Bin and Elfving Anders and Yang Zhaochu and Nhut, \{Tran Minh\} and Halvorsen Einar and H{\o}ivik Nils",
year = "2009",
doi = "10.1109/IPFA.2009.5232614",
language = "英语",
isbn = "9781424439102",
series = "Proceedings of the International Symposium on the Physical and Failure Analysis of Integrated Circuits, IPFA",
pages = "438--442",
booktitle = "Proceedings of the 2009 16th IEEE International Symposium on the Physical and Failure Analysis of Integrated Circuits, IPFA 2009",
note = "2009 16th IEEE International Symposium on the Physical and Failure Analysis of Integrated Circuits, IPFA 2009 ; Conference date: 06-07-2009 Through 10-07-2009",
}