TY - JOUR
T1 - Phase Voltage and Current Fault Components Based Fault Segment Location Method Under Single-Phase Earth Fault in Distribution Network
AU - Chang, Zhongxue
AU - Song, Guobing
AU - Huang, Wei
AU - Guo, Shanghua
AU - Zhang, Wei
N1 - Publisher Copyright:
© 2017, Power System Technology Press. All right reserved.
PY - 2017/7/5
Y1 - 2017/7/5
N2 - To overcome the shortcomings of existing fault segment location methods that considerable communication is needed and zero-sequence voltage and current are difficult to measure, a method based on phase voltage and current fault components was proposed. It is obtained that when a single-phase earth fault occurs, there will be positive correlation coefficients between current and voltage fault component derivative of each phase of healthy lines, healthy phases of fault line and fault phase of downstream segments of the fault point respectively. On contrary, the correlation coefficients of upstream segments of fault point are negative. Therefore, the farthest segment away from the bus among the segments with negative correlation coefficient is the faulty one. If all correlation coefficients are positive, the fault occurs at the bus. Simulation on PSCAD verifies reliability of proposed method in all types of faults.
AB - To overcome the shortcomings of existing fault segment location methods that considerable communication is needed and zero-sequence voltage and current are difficult to measure, a method based on phase voltage and current fault components was proposed. It is obtained that when a single-phase earth fault occurs, there will be positive correlation coefficients between current and voltage fault component derivative of each phase of healthy lines, healthy phases of fault line and fault phase of downstream segments of the fault point respectively. On contrary, the correlation coefficients of upstream segments of fault point are negative. Therefore, the farthest segment away from the bus among the segments with negative correlation coefficient is the faulty one. If all correlation coefficients are positive, the fault occurs at the bus. Simulation on PSCAD verifies reliability of proposed method in all types of faults.
KW - Fault component
KW - Phase voltage and current
KW - Segment location
KW - Single-phase earth fault
KW - Smart distribution network
UR - https://www.scopus.com/pages/publications/85029645870
U2 - 10.13335/j.1000-3673.pst.2016.2994
DO - 10.13335/j.1000-3673.pst.2016.2994
M3 - 文章
AN - SCOPUS:85029645870
SN - 1000-3673
VL - 41
SP - 2363
EP - 2369
JO - Dianwang Jishu/Power System Technology
JF - Dianwang Jishu/Power System Technology
IS - 7
ER -