Skip to main navigation Skip to search Skip to main content

Periprosthetic femoral fracture - a biomechanical comparison between vancouver type B1 and B2 fixation methods

  • Mehran Moazen
  • , Jonathan H. Mak
  • , Lee W. Etchels
  • , Zhongmin Jin
  • , Ruth K. Wilcox
  • , Alison C. Jones
  • , Eleftherios Tsiridis

Research output: Contribution to journalArticlepeer-review

60 Scopus citations

Abstract

Current clinical data suggest a higher failure rate for internal fixation in Vancouver type B1 periprosthetic femoral fracture (PFF) fixations compared to long stem revision in B2 fractures. The aim of this study was to compare the biomechanical performance of several fixations in the aforementioned fractures. Finite element models of B1 and B2 fixations, previously corroborated against in vitro experimental models, were compared. The results indicated that in treatment of B1 fractures, a single locking plate can be without complications provided partial weight bearing is followed. In case of B2 fractures, long stem revision and bypassing the fracture gap by two femoral diameters are recommended. Considering the risk of single plate failure, long stem revision could be considered in all comminuted B1 and B2 fractures.

Original languageEnglish
Pages (from-to)495-500
Number of pages6
JournalJournal of Arthroplasty
Volume29
Issue number3
DOIs
StatePublished - Mar 2014

Keywords

  • Finite element method
  • Fracture
  • Stiffness
  • Strain
  • Vancouver type B

Fingerprint

Dive into the research topics of 'Periprosthetic femoral fracture - a biomechanical comparison between vancouver type B1 and B2 fixation methods'. Together they form a unique fingerprint.

Cite this