Performance of cone meter for measuring cryogenic fluid considering cavitation

  • Denghui He
  • , Zhuang Chang
  • , Bofeng Bai
  • , Senlin Chen
  • , Pengcheng Guo
  • Xi'an University of Technology

Research output: Contribution to journalArticlepeer-review

2 Scopus citations

Abstract

The performance of the cone meter when measuring the cryogenic fluid was investigated by numerical simulation. The results show that the discharge coefficient and pressure loss coefficient of the cone meter are almost constant when the Reynolds number in the “stable region”. The cryogenic fluids, especially the liquid hydrogen, have wider stable Reynolds number ranges than the water. There is little effect of cavitation on the discharge coefficient and pressure loss coefficient at the initial stage of cavitation. Thus the effect of slight cavitation on the measurement error of the flow rate is small, whose relative error is less than ±0.5% in present cases. This study opens a new avenue for measuring the flow rate of the cryogenic fluid.

Original languageEnglish
Pages (from-to)12-21
Number of pages10
JournalInternational Journal of Fluid Machinery and Systems
Volume12
Issue number1
DOIs
StatePublished - 2019

Keywords

  • Cone meter
  • Cryogenic fluid
  • Discharge coefficient
  • Flow rate measurement
  • Pressure loss coefficient