Abstract
A combined heating and power system (CHP) driven by natrual gas was established based on solid oxide fuel cell (SOFC), relevant SOFC heat and mass transfer equations as well as electrochemical equations were deduced, and component models were built and solved by FORTRAN as a tool to predict the system performance of a 1 kW residential SOFC-CHP system. The results indicate that the system efficiency is much higher than the generating efficiency of SOFC under the design-point condition. A maximum value of electric power appears with the increase of the inlet fuel flow, fuel utilization and electric efficiency decrease, system cogeneration efficiency experiences a rising trend, and the cell temperature gradient distribution becomes growingly even. Reducing the excess air ratio could enhance the system performance. The above conclusions are very useful for the design and optimization of the residential SOFC-CHP system.
| Original language | English |
|---|---|
| Pages (from-to) | 604-609 |
| Number of pages | 6 |
| Journal | Taiyangneng Xuebao/Acta Energiae Solaris Sinica |
| Volume | 32 |
| Issue number | 4 |
| State | Published - Apr 2011 |
UN SDGs
This output contributes to the following UN Sustainable Development Goals (SDGs)
-
SDG 7 Affordable and Clean Energy
Keywords
- CHP
- Efficiency
- Performance analysis
- SOFC
Fingerprint
Dive into the research topics of 'Performance analysis of 1 kW residential SOFC-CHP system'. Together they form a unique fingerprint.Cite this