Skip to main navigation Skip to search Skip to main content

Particle swarm and multi-objective optimization algorithm for heat sink configuration of a two-stage precision thermoelectric refrigeration

  • Xi'an Jiaotong University
  • Ltd.

Research output: Contribution to journalArticlepeer-review

1 Scopus citations

Abstract

Two-stage cascade thermoelectric coolers (TECs) face performance limitations in practical applications due to inefficient heat sink configurations, which hinders the simultaneous maximization of cooling capacity and coefficient of performance. To solve this problem, this study establishes a one-dimensional thermoelectric energy model integrated with a heat sink thermal conductance. Combined with the Particle Swarm Optimization and the multi-objective optimization algorithm, the single-objective (maximum cooling capacity Qc or maximum cooling coefficient of performance COPc) and multi-objective (COPc-Qc trade-off) optimization problems are analyzed, respectively. The research results show that for single-objective optimization, it reveals the relationship between the optimal thermal conductance distribution ratio (ZUA) and input current. In the optimization for maximizing Qc, when the total thermal conductance (UAhx) is 12 W/K, the results show that the optimal ZUA is 0.685, corresponding to an optimal input current of 8.12A. And the Qc reaches its maximum value of 13.89W and COPc is 0.107. In the optimization of maximizing COPc, the optimal ZUA is 0.645, corresponding to the optimal input current of 2.52A. Meanwhile, COPc reaches the maximum value of 0.314 and Qc is 4.78W. Furthermore, high ZUA could enhance COPc but limit Qc, while low ZUA is beneficial to Qc but weakens the enhancement effect of COPc. The TOPSIS decision indicates that under the given operating conditions, the performance COPc and Qc of the two-stage cascade thermoelectric cooler are 0.219 and 9.36W respectively, and the ZUA and input current are 0.66 and 4.49A, respectively. Finally, in practical applications, the optimal solution should be selected based on the actual demand. For instance, when prioritizing cooling capacity, a high Qc solution should be chosen, while in energy-constrained scenarios, a high COPc solution should be emphasized.

Original languageEnglish
Article number139477
JournalEnergy
Volume341
DOIs
StatePublished - 30 Dec 2025

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 7 - Affordable and Clean Energy
    SDG 7 Affordable and Clean Energy

Keywords

  • Heat sink configuration
  • Multi-objective optimization
  • Thermoelectric cooler
  • Two-stage cascade