TY - JOUR
T1 - Parent, alkylated, oxygenated and nitrated polycyclic aromatic hydrocarbons in PM2.5 emitted from residential biomass burning and coal combustion
T2 - A novel database of 14 heating scenarios
AU - Zhang, Yue
AU - Shen, Zhenxing
AU - Sun, Jian
AU - Zhang, Leiming
AU - Zhang, Bin
AU - Zou, Haijiang
AU - Zhang, Tian
AU - Hang Ho, Steven Sai
AU - Chang, Xiaojian
AU - Xu, Hongmei
AU - Wang, Tao
AU - Cao, Junji
N1 - Publisher Copyright:
© 2020 Elsevier Ltd
PY - 2021/1/1
Y1 - 2021/1/1
N2 - To characterize the emissions of polycyclic aromatic hydrocarbons (PAHs) from residential biomass burning and coal combustion in field environments, smoke samples were collected from the combustion of six types of biomass in heated kangs and four types of coal in traditional stoves and semi-gasifier stoves. The emission factors (EFs) of the total PAH were in the range of 84.5–344 mg/kg for biomass burning, with lower EFs for biomass with higher densities, and in the range of 38.0–206 mg/kg for coal combustion, with lower EFs for coals with higher maturity. Moreover, EFs were lower from high-density biomass fuels (wood trunk, 84.5 ± 11.3 mg/kg) than low-maturity coals (bituminous coal, 206 ± 16.5 mg/kg). Parent, oxygenated, alkylated, and nitrated PAHs accounted for 81.1%, 12.6%, 6.2%, and 0.1%, respectively, of the total-PAH EFs from biomass burning, and 84.7%, 13.8%, 1.4%, and 0.1%, respectively, of the total-PAH EFs from coal combustion. PAH source profiles differed negligibly between biomass fuels but differed significantly between bituminous coal and anthracite coal fuels. The characteristic species of sources were phenanthrene, 9-fluorenone, and 2-nitrobiphenyl for biomass burning, and were phenanthrene, benzo[ghi]perylene, 1,4-naphthoquinone, and 2-nitrobiphenyl for coal combustion. The ratios of benzo[b]fluoranthene/(benzo[b]fluoranthene + benzo[k]fluoranthene) were 0.40–0.45 for biomass burning and 0.89–0.91 for coal combustion, and these significantly different values constitute unique markers for distinguishing these fuels in source apportionment. Benzo[a]pyrene-equivalent factor emissions were 2.79–11.3 mg/kg for biomass and 7.49–41.9 mg/kg for coal, where parent PAHs contributed 92.0%–95.1% from biomass burning and 98.6%–98.8% from coal combustion. Total-PAH emissions from residential heating were 1552 t across Shaanxi province, to which wheat straw (445 t) in biomass burning and bituminous coal (438 t) in coal combustion were the highest contributors. Results from this study provide crucial knowledge for the source identification of PAHs as well as for the design of abatement strategies against pollutant emissions.
AB - To characterize the emissions of polycyclic aromatic hydrocarbons (PAHs) from residential biomass burning and coal combustion in field environments, smoke samples were collected from the combustion of six types of biomass in heated kangs and four types of coal in traditional stoves and semi-gasifier stoves. The emission factors (EFs) of the total PAH were in the range of 84.5–344 mg/kg for biomass burning, with lower EFs for biomass with higher densities, and in the range of 38.0–206 mg/kg for coal combustion, with lower EFs for coals with higher maturity. Moreover, EFs were lower from high-density biomass fuels (wood trunk, 84.5 ± 11.3 mg/kg) than low-maturity coals (bituminous coal, 206 ± 16.5 mg/kg). Parent, oxygenated, alkylated, and nitrated PAHs accounted for 81.1%, 12.6%, 6.2%, and 0.1%, respectively, of the total-PAH EFs from biomass burning, and 84.7%, 13.8%, 1.4%, and 0.1%, respectively, of the total-PAH EFs from coal combustion. PAH source profiles differed negligibly between biomass fuels but differed significantly between bituminous coal and anthracite coal fuels. The characteristic species of sources were phenanthrene, 9-fluorenone, and 2-nitrobiphenyl for biomass burning, and were phenanthrene, benzo[ghi]perylene, 1,4-naphthoquinone, and 2-nitrobiphenyl for coal combustion. The ratios of benzo[b]fluoranthene/(benzo[b]fluoranthene + benzo[k]fluoranthene) were 0.40–0.45 for biomass burning and 0.89–0.91 for coal combustion, and these significantly different values constitute unique markers for distinguishing these fuels in source apportionment. Benzo[a]pyrene-equivalent factor emissions were 2.79–11.3 mg/kg for biomass and 7.49–41.9 mg/kg for coal, where parent PAHs contributed 92.0%–95.1% from biomass burning and 98.6%–98.8% from coal combustion. Total-PAH emissions from residential heating were 1552 t across Shaanxi province, to which wheat straw (445 t) in biomass burning and bituminous coal (438 t) in coal combustion were the highest contributors. Results from this study provide crucial knowledge for the source identification of PAHs as well as for the design of abatement strategies against pollutant emissions.
KW - Benzo[a]pyrene-equivalent factor emissions
KW - Field experiments
KW - PAHs emissions
KW - Rural heating
KW - Source profiles
UR - https://www.scopus.com/pages/publications/85093671187
U2 - 10.1016/j.envpol.2020.115881
DO - 10.1016/j.envpol.2020.115881
M3 - 文章
C2 - 33120337
AN - SCOPUS:85093671187
SN - 0269-7491
VL - 268
JO - Environmental Pollution
JF - Environmental Pollution
M1 - 115881
ER -