Abstract
Large superconducting magnets such as ITER (International Thermonuclear Experimental Research) or KSTAR (Korean Superconducting Tokamak Advanced Research) magnet system adopted a cable-in-conduit conductor (CICC) using a forced-flow cooling system. Main optimization criteria for the conductor design of superconducting magnet system are stability margin and CICC cooling requirements. A zero-dimensional method is applied for the calculation of stability and the conductor optimization. In order to increase conductor performance, three different strands, ITER HP-I and HP-II, and KSTAR HP-III, are tested. The strand characteristics of KSTAR HP-III are measured in the Samsung's PPMS and Jc measurement system, and applied for this study. Also, the strand diameters, 0.81 mm and 0.78 mm are considered for this study, due to design change. Based on this result, the proposed configuration of CICC has been fabricated.
| Original language | English |
|---|---|
| Pages (from-to) | 227-234 |
| Number of pages | 8 |
| Journal | KSME International Journal |
| Volume | 16 |
| Issue number | 2 |
| DOIs | |
| State | Published - Feb 2002 |
Keywords
- CICC
- Conductor Performance
- Stability
- Superconducting Magnet
Fingerprint
Dive into the research topics of 'Parametric study for conductor design of KSTAR PF coils'. Together they form a unique fingerprint.Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver