Skip to main navigation Skip to search Skip to main content

Parametric perfusion imaging with single-pixel resolution and high signal to clutter ratio

  • DIya Wang
  • , Xuan Yang
  • , Mengnan Xiao
  • , Hong Hu
  • , Hui Zhong
  • , Mingxi Wan
  • Xi'an Jiaotong University

Research output: Chapter in Book/Report/Conference proceedingConference contributionpeer-review

5 Scopus citations

Abstract

Parametric perfusion imaging (PPI) based on time-intensity-curves (TICs) can quantify and depict the spatial distribution of tumor perfusion information in liver cancer research. However, accurate diagnosis of PPI is seriously disturbed by the fluctuations of TICs and decreases of coded threshold induced by no-microbubble (MB) regions. Such disturbances, particularly the decrease of signal-to-clutter ratio (SCR) of TICs, are further exacerbated during selecting single-pixel region-of-interest (ROI) to obtain PPI with highest resolution. The objective of this study was to accurately obtain PPI with single-pixel resolution at the smallest ROI by the valid TICs filtration and the SCR enhancement of TICs. First, single-pixel TICs were obtained from the dynamic contrast images of a patient with gallbladder carcinoma liver metastasis. Next, these TICs in no-MB regions were then eliminated due to their low correlation with MB regions. Whereas the valid reserved TICs were filtered by the detrended fluctuation analysis to improve their SCR. Color-coded images were finally obtained based on the perfusion parameters extracted from the reserved TICs. After TICs filtration and denoising, the disturbances from no-MB regions were effectively removed; SCR of TICs was enhanced by 5.49 ± 0.34 dB; and operation time of PPI decreased 50.4 ± 0.1% because lots of invalid data were eliminated. Hot spots distribution and perfusion characteristic of neovascularization in the liver metastases were accurately distinguished and depicted by combining PPI with single-pixel resolution, especially the wash in time and wash out time. Besides, edge features of the invasion area and liver were clearly described without extra segmentation algorithm. It can contribute to accurately make a clinical decision in the liver cancer diagnoses by the single-pixel resolution PPI with comprehensive functional perfusion information.

Original languageEnglish
Title of host publication2015 IEEE International Ultrasonics Symposium, IUS 2015
PublisherInstitute of Electrical and Electronics Engineers Inc.
ISBN (Electronic)9781479981823
DOIs
StatePublished - 13 Nov 2015
EventIEEE International Ultrasonics Symposium, IUS 2015 - Taipei, Taiwan, Province of China
Duration: 21 Oct 201524 Oct 2015

Publication series

Name2015 IEEE International Ultrasonics Symposium, IUS 2015

Conference

ConferenceIEEE International Ultrasonics Symposium, IUS 2015
Country/TerritoryTaiwan, Province of China
CityTaipei
Period21/10/1524/10/15

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Keywords

  • detrended fluctuation analysis
  • filtration
  • parametric perfusion imaging
  • signal-to-clutter ratio
  • single pixel resolution
  • time-intensity curve

Fingerprint

Dive into the research topics of 'Parametric perfusion imaging with single-pixel resolution and high signal to clutter ratio'. Together they form a unique fingerprint.

Cite this