Abstract
The effect of the length to diameter ratio of a pulse tube on the performance of pulse tube refrigerator (PTR) was studied numerically. It is found that there exists an optimum length to diameter ratio at which the cooling capacity of a PTR is the maximum. The value of the optimum ratio varies with structure and operation parameters (such as frequency). For a PTR of conventional structure with a frequency of 17 Hz the optimum ratio is found to be 9.0.
| Original language | English |
|---|---|
| Pages (from-to) | 230-232 |
| Number of pages | 3 |
| Journal | Hsi-An Chiao Tung Ta Hsueh/Journal of Xi'an Jiaotong University |
| Volume | 36 |
| Issue number | 3 |
| State | Published - Mar 2002 |
Keywords
- Length to diameter ratio
- Numerical simulation
- Pulse tube refrigerator
Fingerprint
Dive into the research topics of 'Optimum design of the length to diameter ratio of the pulse tube by theory and numerical simulation'. Together they form a unique fingerprint.Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver