Skip to main navigation Skip to search Skip to main content

Optimum design of the length to diameter ratio of the pulse tube by theory and numerical simulation

  • Xi'an Jiaotong University

Research output: Contribution to journalArticlepeer-review

2 Scopus citations

Abstract

The effect of the length to diameter ratio of a pulse tube on the performance of pulse tube refrigerator (PTR) was studied numerically. It is found that there exists an optimum length to diameter ratio at which the cooling capacity of a PTR is the maximum. The value of the optimum ratio varies with structure and operation parameters (such as frequency). For a PTR of conventional structure with a frequency of 17 Hz the optimum ratio is found to be 9.0.

Original languageEnglish
Pages (from-to)230-232
Number of pages3
JournalHsi-An Chiao Tung Ta Hsueh/Journal of Xi'an Jiaotong University
Volume36
Issue number3
StatePublished - Mar 2002

Keywords

  • Length to diameter ratio
  • Numerical simulation
  • Pulse tube refrigerator

Fingerprint

Dive into the research topics of 'Optimum design of the length to diameter ratio of the pulse tube by theory and numerical simulation'. Together they form a unique fingerprint.