Abstract
The turn-table platform stirring technique is used to improve the measurement accuracy of a reverberation chamber (RC). It is usually assumed that the half-wavelength platform spatial sampling results in independent samples, which can be used to approximate the independent platform sample number. But the approximation is rather coarse. This paper presents a measurement-based method to determine the independent platform sample number. This method is simple and accurate. In contrast to the half-wavelength coarse approximation that depends only on frequency, this method in addition illustrates the dependence of the independent platform sample number on RC loading and mode stirring.
| Original language | English |
|---|---|
| Article number | 6334445 |
| Pages (from-to) | 1306-1309 |
| Number of pages | 4 |
| Journal | IEEE Transactions on Electromagnetic Compatibility |
| Volume | 54 |
| Issue number | 6 |
| DOIs | |
| State | Published - 2012 |
| Externally published | Yes |
Keywords
- Independent samples
- platform stirring
- reverberation chamber (RC)
Fingerprint
Dive into the research topics of 'On independent platform sample number for reverberation chamber measurements'. Together they form a unique fingerprint.Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver