TY - GEN
T1 - Numerical study on forced convective heat transfer in porous pin fin channels
AU - Yang, Jian
AU - Zeng, Min
AU - Wang, Qiuwang
PY - 2009
Y1 - 2009
N2 - Pin fin heat exchanges are often used in cooling of high thermal loaded electronic components due to their excellent heat transfer performance. However, the pressure drop in such heat exchanges is usually much higher than that in others, so their overall heat transfer performance is seriously reduced. In order to reduce the pressure drop and improve the overall heat transfer performance for pin fin heat exchangers, porous metal pin arrays are used and the performance of fluid flow and heat transfer in heat exchanger unit cells are numerically studied. The Forchheimer-Brinkman extended Darcy model and two-equation heat transfer model for porous media are employed and the effects of Reynolds number (Re), permeability (AT) and pin fin cross-section forms are studied in detail. The results show that, with proper selection of governing parameters, the overall heat transfer performance of porous pin fin heat exchanger is much better than that of traditional solid pin fin heat exchanger; the overall heat transfer performance of long elliptic porous pin fin heat exchanger is the best, that is, the heat transfer per unit pressure drop of such heat exchanger is the highest and the maximum value of the heat transfer over pressure drop is obtained at K=2×10-7 m2.
AB - Pin fin heat exchanges are often used in cooling of high thermal loaded electronic components due to their excellent heat transfer performance. However, the pressure drop in such heat exchanges is usually much higher than that in others, so their overall heat transfer performance is seriously reduced. In order to reduce the pressure drop and improve the overall heat transfer performance for pin fin heat exchangers, porous metal pin arrays are used and the performance of fluid flow and heat transfer in heat exchanger unit cells are numerically studied. The Forchheimer-Brinkman extended Darcy model and two-equation heat transfer model for porous media are employed and the effects of Reynolds number (Re), permeability (AT) and pin fin cross-section forms are studied in detail. The results show that, with proper selection of governing parameters, the overall heat transfer performance of porous pin fin heat exchanger is much better than that of traditional solid pin fin heat exchanger; the overall heat transfer performance of long elliptic porous pin fin heat exchanger is the best, that is, the heat transfer per unit pressure drop of such heat exchanger is the highest and the maximum value of the heat transfer over pressure drop is obtained at K=2×10-7 m2.
KW - Forced convective heat transfer
KW - Numerical computation
KW - Porous pin fin heat exchanger
UR - https://www.scopus.com/pages/publications/70349189892
M3 - 会议稿件
AN - SCOPUS:70349189892
SN - 9780791848487
T3 - 2008 Proceedings of the ASME Summer Heat Transfer Conference, HT 2008
SP - 17
EP - 21
BT - 2008 Proceedings of the ASME Summer Heat Transfer Conference, HT 2008
T2 - 2008 ASME Summer Heat Transfer Conference, HT 2008
Y2 - 10 August 2008 through 14 August 2008
ER -