Abstract
To improve heat transfer performance and reduce erosion of economizers in coal-fired power plants, firstly the heat transfer and erosion characteristics is numerically studied for the single H-type finned oval tube with enhanced heat transfer structures including bleeding dimples, longitudinal vortex generators (LVGs), and compound dimple-LVG. The simulation results show that the oval tube with compound LVG-dimple achieves the highest overall heat transfer performance while the oval tube with LVG works most efficiently in the anti-wear performance. Then based on the H-type finned oval tube, the LVG structure on the first row of tubes together with hemisphere protrusions design, while the compound LVG-dimple on the rest tubes are also simulated. The optimized H-type finned oval tube bank heat exchanger is demonstrated of high performance on both heat transfer and anti-wear.
| Original language | English |
|---|---|
| Pages (from-to) | 93-104 |
| Number of pages | 12 |
| Journal | Applied Energy |
| Volume | 127 |
| DOIs | |
| State | Published - 15 Aug 2014 |
UN SDGs
This output contributes to the following UN Sustainable Development Goals (SDGs)
-
SDG 7 Affordable and Clean Energy
Keywords
- Dimple
- Erosion
- Heat transfer
- Longitudinal vortex generators
Fingerprint
Dive into the research topics of 'Numerical investigation of heat transfer and erosion characteristics for H-type finned oval tube with longitudinal vortex generators and dimples'. Together they form a unique fingerprint.Cite this