TY - GEN
T1 - Numerical investigation of a cryogenic liquid turbine performance and flow behavior
AU - Zhao, Wei
AU - Sun, Jinju
AU - Zhu, Hezhao
AU - Li, Cheng
AU - Cai, Guocheng
AU - Ma, Guohong
PY - 2008
Y1 - 2008
N2 - A single stage cryogenic liquid turbine is designed for a large-scale internal compression air-separation unit to replace the Joule-Thompson valve and recover energy from the liquefied air during throttling process. It includes a radial vaned nozzle, and 3-dimensional impeller. Numerical investigation using 3-D incompressible Navier-Stokes Equation together with Spalart-Allmaras turbulence model and mixing plane approach at the impeller and stator interface are carried out at design and off-design flow. At design condition, recovered shaft power has amounted to 185.87 kW, and pressure in each component decreases smoothly and reaches to the expected scale at outlet. At small flow rates, flow separation is observed near the middle section of blade suction surface, which may cause local vaporization and even cavitation. To further improve the turbine flow behavior and performance, geometry parametric study is carried out. Influence of radial gap between impeller and nozzle blade rows, and nozzle stagger angle on turbine performance are investigated and clarified. Results arising from the present study provide some guidance for cryogenic liquid turbine optimal design.
AB - A single stage cryogenic liquid turbine is designed for a large-scale internal compression air-separation unit to replace the Joule-Thompson valve and recover energy from the liquefied air during throttling process. It includes a radial vaned nozzle, and 3-dimensional impeller. Numerical investigation using 3-D incompressible Navier-Stokes Equation together with Spalart-Allmaras turbulence model and mixing plane approach at the impeller and stator interface are carried out at design and off-design flow. At design condition, recovered shaft power has amounted to 185.87 kW, and pressure in each component decreases smoothly and reaches to the expected scale at outlet. At small flow rates, flow separation is observed near the middle section of blade suction surface, which may cause local vaporization and even cavitation. To further improve the turbine flow behavior and performance, geometry parametric study is carried out. Influence of radial gap between impeller and nozzle blade rows, and nozzle stagger angle on turbine performance are investigated and clarified. Results arising from the present study provide some guidance for cryogenic liquid turbine optimal design.
UR - https://www.scopus.com/pages/publications/69949169295
U2 - 10.1115/GT2008-50391
DO - 10.1115/GT2008-50391
M3 - 会议稿件
AN - SCOPUS:69949169295
SN - 9780791843161
T3 - Proceedings of the ASME Turbo Expo
SP - 2287
EP - 2295
BT - 2008 Proceedings of the ASME Turbo Expo
T2 - 2008 ASME Turbo Expo
Y2 - 9 June 2008 through 13 June 2008
ER -